6SL3520-1XN04-0AF0 Siemens - SINAMICS G115D wall-mounted Rated power: 4 kW for 3S 200%, 57S 150%, 240S 87% Radio interference suppression filter for Cat. C2 3AC380-480V+10/-10% 45-66Hz Ambient temp. -30 to +40°C size: FSB Protection class IP65/66 / UL Type 4X brake voltage 180 V DC repair switch Q4/2 for 400 V AC and M12 for I/O and communication with integrated 24 V DC PSU with looping through Fieldbus integrated: PROFINET PN, Ethernet IP

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6SL3520-1XN04-0AF0
Product Description SINAMICS G115D wall-mounted Rated power: 4 kW for 3S 200%, 57S 150%, 240S 87% Radio interference suppression filter for Cat. C2 3AC380-480V+10/-10% 45-66Hz Ambient temp. -30 to +40°C size: FSB Protection class IP65/66 / UL Type 4X brake voltage 180 V DC repair switch Q4/2 for 400 V AC and M12 for I/O and communication with integrated 24 V DC PSU with looping through Fieldbus integrated: PROFINET PN, Ethernet IP
Product family Not available
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 12 Day/Days
Net Weight (kg) 14,040 Kg
Packaging Dimension 560,00 x 180,00 x 315,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515992110
UPC 195125523104
Commodity Code 85044095
LKZ_FDB/ CatalogID D31.2
Product Group X01L
Group Code R220
Country of origin Great Britain
Compliance with the substance restrictions according to RoHS directive Since: 16.07.2020
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Dodecachloropentacyclo[12... > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Dodecachloropentacyclo[12.2.1.16,9.02,13.05,10]octadeca-7,15-diene (“Dechlorane Plus”™) covering any of its individual anti- and syn-isomers or any combination thereof Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Diboron trioxide CAS-No. 1303-86-2 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Diboron trioxide Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-(2H-benzotriazol-2... CAS-No. 3147-75-9 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-(2H-benzotriazol-2-yl)-4-(1,1,3,3-tetramethylbutyl)phenol (UV-329) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Rated Data

Input
Number Of Phases 3 Ac
Line Voltage 380 ... 480 V +10 % -10 %
Line Frequency 45 ... 66 Hz
Rated Current 8.95 A
Output
Number Of Phases 3 Ac
Rated Voltage 400 V
Rated Power Iec 400V (Ho) 4.00 Kw
Rated Power Nec 480V (Ho) 5.40 Hp
Rated Current (Ho) 10.20 A
Max. Output Current 20.40 A
Pulse Frequency 4 Khz
Output Frequency For Vector Control 0 ... 240 Hz
Output Frequency For V/F Control 0 ... 550 Hz
Overload Capability
High Overload (Ho)
200% × Base Load Current Ih For 3 S, Followed By 150% For 57 S Within A Cycle
Time Of 300S

Inputs / Outputs

Standard Digital Inputs
Number 1) 4
Switching Level: 0 → 1 11 V
Switching Level: 1 → 0 5 V
Max. Inrush Current 15 Ma

Fail-Safe Digital Inputs

Number 1
Digital Inputs / Outputs Parameterizable
Number 2
Ptc/ Kty Interface
1 Motor Temperature Sensor Input, Possible Sensor Ptc, Kty, Pt1000, Thermo
Click, Accuracy ±5 °Cgeneral Tech. Specifications
Power Factor Λ 0.00 ... 0.89
Offset Factor Cos Φ 0.99
Efficiency Η 0.97
Power Loss 0.173 Kw
Filter Class (Integrated) Rfi Suppression Filter For Category C2
Brake Voltage 180V Dc (Default)
Integrated Braking Resistor (Continuous
Braking Power P_Db / Peak Power
P_Max)10W / 100W

Ambient Conditions

Cooling Air Cooled By Integrated Fan
Installation Altitude 1,000 M (3,280.84 Ft)
Ambient Temperature
Operation -30 ... 55 °C (-22 ... 131 °F)
Transport -40 ... 70 °C (-40 ... 158 °F)
Storage -40 ... 70 °C (-40 ... 158 °F)
Relative Humidity
Max. Operation95 % At 40 °C (104 °F), Condensation
And Icing Not Permissible

Mechanical Data

Degree Of Protection Ip65/66 / Ul Type 4X
Frame Size Fsb
Net Weight 8.58 Kg (18.87 Lb)

Dimensions

Width 425 Mm (16.73 In)
Height 240 Mm (9.45 In)
Depth 169 Mm (6.65 In)
Closed-Loop Control Techniques
V/F Linear / Square-Law / Parameterizable Yes
V/F With Flux Current Control (Fcc) Yes
V/F Eco Linear / Square-Law Yes
Sensorless Vector Control Yes
Vector Control, With Sensor No
Encoderless Torque Control Yes
Torque Control, With Encoder No

Communication

Communication Profinet, Ethernet/Ip
Version M12
Control Option
Control Option Repair Switch
Article No. : 6Sl3520-1Xn04-0Af0
Technical Data Are Subject To Change! There May Be Discrepancies Between Calculated And Rating Plate Values. Page 2 Of 2 Generated Fri Dec 20 13:35:26 Cet 2024

Connections

Connection Type
Version Connector With Daisy Chain
3Ac 400V Supply
Version 2X Q4/2
24 V Dc Power Supply
Variant Integrated
Version Integrated

Digital I/O

Version M12
Motor
Version Q8/0
External Brake Resistor
Version Cable Gland (Standard)
Pe Connection
Version On Housing With M5 Screw

Max. Motor Cable Length

Shielded 15 M (49.21 Ft)
Converter Losses To Iec61800-9-2*
Efficiency Class Ie2
Comparison With The Reference
Converter (90% / 100%)36.25 %
The Percentage Values Show The Losses In Relation To The Rated Apparent Power Of
The Converter.
The Diagram Shows The Losses For The Points (As Per Standard Iec61800-9-2) Of
The Relative Torque Generating Current (I) Over The Relative Motor Stator Frequency
(F). The Values Are Valid For The Basic Version Of The Converter Without
Options/Components.
*Calculated Valuesstandards
Compliance With Standards Ul, Cul, Ce, C-Tick (Rcm), Eac, Kcc,
Semi F47, Reach
Ce Marking Emc Directive 2014/30/Ec, Low-Voltage
Directive 2014/35/Ec
1)4 Inputs Pnp, Not Isolated, Additional 2X Switcheable Di/Do
117.0 W (1.7 %)
104.0 W (1.5 %)151.0 W (2.1 %) 160.0 W (2.3 %) 173.0 W (2.4 %)
127.0 W (1.8 %) 122.0 W (1.7 %)
106.0 W (1.5 %)
F 90% 50%25%50%I
100%

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible