Siemens

6ES7238-5XA32-0XB0

6ES7238-5XA32-0XB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7238-5XA32-0XB0 Siemens

6ES7238-5XA32-0XB0 Siemens - SM 1238 Energy Meter 480V AC

Extended Description for 6ES7238-5XA32-0XB0 Siemens

6ES7238-5XA32-0XB0 Siemens - SIMATIC S7-1200. Analog input. SM 1238 Energy Meter 480V AC. Energy measurement module for recording electrical parameters in 1 and 3 phase networks (TN. TT) up to 480VAC; current range: 1A. 5A; recording of voltages. currents. phase angels. power. energy values. frequencies; channel diagnosis

Free Delivery to UK Mainland on orders over £25

Manufacturer New

1 available
2 - 5 w.days
£439.87 Exc. VAT
£527.84 Inc. VAT

Manufacturer New

3 available
5 - 8 w.days
£372.51 Exc. VAT
£447.01 Inc. VAT

Direct from Manufacturer

Fetching stock
2 - 3 W.Weeks

£283.86 Exc. VAT
£340.64 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7238-5XA32-0XB0
Product Description SIMATIC S7-1200, Analog input, SM 1238 Energy Meter 480 V AC, power measurement module for data acquisition in 1- and 3-phase supply systems (TN, TT) up to 480 V AC; Current range: 1 A, 5A; acquisition of voltage, current, phase angles, power, energy values, frequencies; Channel diagnostics
Product family SM 1238 Energy Meter 480 V AC analog input modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : EAR99H
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,183 Kg
Packaging Dimension 8,80 x 10,50 x 5,40
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4034106030575
UPC 804766341809
Commodity Code 85389091
LKZ_FDB/ CatalogID ST72
Product Group 4508
Group Code R132
Country of origin China
Compliance with the substance restrictions according to RoHS directive Since: 22.04.2016
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Voltage Measurement Yes
— With Voltage Transformer Yes
Current Measurement Yes
— Without Current Transformer No
— With Current Transformer Yes
Energy Measurement Yes
Frequency Measurement Yes
Power Measurement Yes
Active Power Measurement Yes
Reactive Power Measurement Yes
I&M Data Yes; I&M 0
Isochronous Mode No
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version V13 Sp1
Operating Mode
Cyclic Measurement Yes
Acyclic Measurement Yes
Acyclic Measured Value Access Yes
Fixed Measured Value Sets Yes
Freely Definable Measured Value Sets No
Cir - Configuration In Run
Reparameterization Possible In Run Yes
Calibration Possible In Run Yes
Installation Type/Mounting
Mounting Position Horizontal, Vertical

Supply Voltage

Design Of The Power Supply From Cpu
Type Of Supply Voltage Dc
Input Current
Current Consumption, Max. 180 Ma
Power Loss
Power Loss , Typ. 0.75 W
Address Area
Address Space Per Module
Address Space Per Module, Max. 124 Byte; 112 Byte Input / 12 Byte Output
Time Of Day
Operating Hours Counter
Present Yes

Analog Inputs

Cycle Time (All Channels), Typ. 50 Ms; Time For Consistent Update Of All Measured And Calculated Values (Cyclic
Und Acyclic Data)
Interrupts/Diagnostics/Status Information
Alarms
Diagnostic Alarm Yes
Limit Value Alarm Yes
Hardware Interrupt No
Diagnostics Indication Led
Monitoring Of The Supply Voltage (Pwr-Led) Yes
Channel Status Display Yes; Green Led
For Channel Diagnostics Yes; Red Fn Led
For Module Diagnostics Yes; Green/Red Diag Led
Integrated Functions

Measuring Functions

Measuring Procedure For Voltage Measurement Trms
Measuring Procedure For Current Measurement Trms
Type Of Measured Value Acquisition Seamless
Curve Shape Of Voltage Sinusoidal Or Distorted
Buffering Of Measured Variables Yes
Parameter Length 74 Byte
Bandwidth Of Measured Value Acquisition 2 Khz; Harmonics: 39 / 50 Hz, 32 / 60 Hz
Measuring Range
— Frequency Measurement, Min. 45 Hz
— Frequency Measurement, Max. 65 Hz
Measuring Inputs For Voltage
— Measurable Line Voltage Between Phase And Neutral
Conductor277 V
— Measurable Line Voltage Between The Line
Conductors480 V
— Measurable Line Voltage Between Phase And Neutral
Conductor, Min.0 V
— Measurable Line Voltage Between Phase And Neutral
Conductor, Max.293 V
— Measurable Line Voltage Between The Line
Conductors, Min.0 V
— Measurable Line Voltage Between The Line
Conductors, Max.508 V
— Internal Resistance Line Conductor And Neutral
Conductor3.4 M Ω
— Power Consumption Per Phase 20 Mw
— Impulse Voltage Resistance 1,2/50Μs 1 Kv
— Measurement Category For Voltage Measurement In
Accordance With Iec 61010-2-030Cat Ii; Cat Iii In Case Of Guaranteed Protection Level Of 1.5 Kv
Measuring Inputs For Current
— Measurable Relative Current (Ac), Min. 1 %; Relative To The Secondary Rated Current 5 A
— Measurable Relative Current (Ac), Max. 100 %; Relative To The Secondary Rated Current 5 A
— Continuous Current With Ac, Maximum Permissible 5 A
— Apparent Power Consumption Per Phase For
Measuring Range 5 A0.6 Va
— Rated Value Short-Time Withstand Current Restricted
To 1 S100 A
— Input Resistance Measuring Range 0 To 5 A 25 M Ω; At The Terminal
— Surge Strength 10 A; For 1 Minute
— Zero Point Suppression Parameterizable: 2 ... 250 Ma, Default 50 Ma
Accuracy Class According To Iec 61557-12
— Measured Variable Voltage 0,2
— Measured Variable Current 0,2
— Measured Variable Apparent Power 0.5
— Measured Variable Active Power 0.5
— Measured Variable Reactive Power 1
— Measured Variable Power Factor 0.5
— Measured Variable Active Energy 0.5
— Measured Variable Reactive Energy 1
— Measured Variable Neutral Current 0.5; Calculated
— Measured Variable Phase Angle ±1 °; Not Covered By Iec 61557-12
— Measured Variable Frequency 0.05
Potential Separation
Potential Separation Channels
Between The Channels And Backplane Bus Yes; 3 700V Ac (Type Test) Cat Iii
Isolation
Isolation Tested With 2 300V Ac For 1 Min. (Type Test)
Standards, Approvals, Certificates
Ce Mark Yes
Csa Approval Yes
Ul Approval Yes
Culus Yes
Fm Approval Yes
Rcm (Formerly C-Tick) Yes
Kc Approval Yes
Marine Approval Yes

Ambient Temperature During Operation

Horizontal Installation, Min. -20 °C
Horizontal Installation, Max. 60 °C
Vertical Installation, Min. -20 °C
Vertical Installation, Max. 50 °C

Dimensions

Width 45 Mm
Height 100 Mm
Depth 75 Mm
Weight S
Weight , Approx. 165 G
Other
Data For Selecting A Current Transformer
Burden Power Current Transformer X/1A, Min. As A Function Of Cable Length And Cross Section, See Device Manual
Burden Power Current Transformer X/5A, Min. As A Function Of Cable Length And Cross Section, See Device Manual

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible