Siemens

3WL1108-3CB32-1AA2

3WL1108-3CB32-1AA2 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3WL1108-3CB32-1AA2 Siemens

3WL1108-3CB32-1AA2 Siemens - fixed-mounted circuit breaker 3-pole, size I, IEC In=800A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

Free Delivery to UK Mainland on orders over £25

Model

Product Brand Name Sentron
Product Designation Acb
Design Of The Product Iec 60947-2
Design Of The Actuating Element Pushbutton
Type Of The Driving Mechanism Manual Operating Mechanism With Mechanical Closing
Type Of The Driving Mechanism / Motor Drive No
Design Of The Overcurrent Release Etu25B

General Technical Data

Number Of Poles 3
Size Of The Circuit-Breaker 1
Utilization Category B
Circuit-Breaker / Design 3Wl1

Voltage

Rated Insulation Voltage Ui 1 000 V
Insulation Voltage / Rated Value 1 000 V
Operating Voltage
At Ac / At 50/60 Hz / Rated Value 690 V

Protection Class

Protection Class Ip Ip20
Protection Class Ip / On The Front Ip20
Protection Function Of The Overcurrent Release Lsi

Dissipation

Power Loss [W]
For Rated Value Of The Current / At Ac / In Hot Operating
State / Per Pole33.3 W
Maximum 100 W

Main Circuit

Operating Frequency
1 / Rated Value 50 Hz
2 / Rated Value 60 Hz

Auxiliary Circuit

Number Of Nc Contacts / For Auxiliary Contacts 2
Number Of No Contacts / For Auxiliary Contacts 2
Suitability
Suitability For Use Plant / Motor Protection

Adjustable Parameters

Adjustable Current Response Value Current / Of The Current-
Dependent Overload Release / Initial Value320 A

Product Component

Trip Indicator Yes
Voltage Trigger No
Undervoltage Release No
Design Of The Auxiliary Switch 2 No + 2 Nc
Product Extension / Optional / Motor Drive Yes

Product Function

Product Function
Grounding Protection No
Phase Failure Detection Yes

Display And Operation

Display Version Without Display
Short Circuit
Operating Short-Circuit Current Breaking Capacity (Ics)
At 415 V / Rated Value 66 Ka
At 500 V / Rated Value 66 Ka
At 690 V / Rated Value 50 Ka
Maximum Short-Circuit Current Breaking Capacity (Icu)
At 415 V / Rated Value 66 Ka
At 500 V / Rated Value 66 Ka
At 690 V / Rated Value 50 Ka

Connections

Arrangement Of Electrical Connectors / For Main Current Circuit Main Connection Rear Side Horizontal
Type Of Electrical Connection / For Main Current Circuit Busbar Connection

Mechanical Design

Height 439.5 Mm
Width 320 Mm
Depth 337 Mm
Fastening Method Fixed Mounting

Environmental Conditions

Ambient Temperature / During Operation
Minimum -20 °C
Maximum 70 °C
Ambient Temperature / During Storage
Minimum -40 °C
Maximum 70 °C

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible