Description for 3UG4513-2BR20 Siemens

3UG4513-2BR20 Siemens - PHASE FAILURE AND SEQUENCE

Extended Description for 3UG4513-2BR20 Siemens

3UG4513-2BR20 Siemens - Analog monitoring relay phase failure and -sequence adjustable undervoltage unbalance 20% fixed 3x 160 to 690V AC 50 to 60 HZ hysteresis 5% fixed delay time 0-20s 2 changeover contacts spring loaded connection

Free Delivery to UK Mainland on orders over £25

Manufacturer New

3 available
2 - 5 w.days
£189.04 Exc. VAT
£226.85 Inc. VAT

Manufacturer New

Available for Back Order
£258.61 Exc. VAT
£310.33 Inc. VAT

Direct from Manufacturer

Fetching stock
2 - 3 W.Weeks

£87.82 Exc. VAT
£105.39 Inc. VAT

Product

Article Number (Market Facing Number) 3UG4513-2BR20
Product Description !!! product phase-out !!! The preferred successor type is 3UG5514-2BR20 phase failure and sequence adjustment undervoltage analog monitoring relay phase failure and sequence adjustable undervoltage asymmetry 20% fixed 3 x 160 to 690 V 50 to 60 Hz AC hysteresis 5% fixed delay time 0-20 s 2 changeover contacts spring-loaded connection system
Product family Line monitoring
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023
Notes The product was replaced with the following successor product: 3UG5514-2BR20 Compare Products

Successor information

Successor 3UG5514-2BR20
Successor Description analog adjustment monitoring relay phase failure, phase sequence, asymmetry and under-voltage monitoring 3x 160-690 V AC, 15-70 Hz 2 changeover contacts spring-loaded terminal

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 0,140 Kg
Packaging Dimension 29,00 x 99,00 x 107,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209642560
UPC 754554960753
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5885
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.05.2012
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Product Function Phase Monitoring Relay
Display Version Led Yes
Insulation Voltage For Overvoltage Category Iii According To
Iec 60664
With Degree Of Pollution 3 Rated Value 690 V
Degree Of Pollution 3
Type Of Voltage
For Monitoring Ac
Of The Control Supply Voltage Ac
Surge Voltage Resistance Rated Value 6 Kv
Shock Resistance According To Iec 60068-2-27 Sinusoidal Half-Wave 15G / 11 Ms
Vibration Resistance According To Iec 60068-2-6 1 ... 6 Hz: 15 Mm, 6 ... 500 Hz: 2G
Mechanical Service Life (Operating Cycles) Typical 10 000 000
Electrical Endurance (Operating Cycles) At Ac-15 At 230 V
Typical100 000
Thermal Current Of The Switching Element With Contacts
Maximum 5 A
Reference Code According To Iec 81346-2 K
Relative Repeat Accuracy 1 %
Substance Prohibitance (Date) 05/01/2012
Svhc Substance Name Lead - 7439-92-1
Lead Monoxide (Lead Oxide) - 1317-36-8
Weight 0.14 Kg

Product Function

Product Function
Undervoltage Detection Yes
Overvoltage Detection No
Phase Sequence Recognition Yes
Phase Failure Detection Yes
Asymmetry Detection Yes
Overvoltage Detection 3 Phase No
Undervoltage Detection 3 Phases Yes
Voltage Window Recognition 3 Phase No
Adjustable Open/Closed-Circuit Current Principle No
Auto-Reset Yes
Control Circuit/
Control Supply Voltage At Ac
At 50 Hz Rated Value 160 ... 690 V
At 60 Hz Rated Value 160 ... 690 V
Operating Range Factor Control Supply Voltage Rated Value At
Ac At 50 Hz
Initial Value 1
Full-Scale Value 1
Operating Range Factor Control Supply Voltage Rated Value At
Ac At 60 Hz
Initial Value 1
Full-Scale Value 1
Measuring Circuit
Measurable Voltage At Ac 160 ... 690 V
Response Time Maximum 450 Ms
Precision
Relative Metering Precision 5 %

Auxiliary Circuit

Number Of Nc Contacts Delayed Switching 0
Number Of No Contacts Delayed Switching 0
Number Of Co Contacts
For Auxiliary Contacts 2
Delayed Switching 2
Operating Frequency With 3Rt2 Contactor Maximum 5 000 1/H

Main Circuit

Number Of Poles For Main Current Circuit 3
Ampacity Of The Output Relay At Ac-15
At 250 V At 50/60 Hz 3 A
At 400 V At 50/60 Hz 3 A
Ampacity Of The Output Relay At Dc-13
At 24 V 1 A
At 125 V 0.2 A
At 250 V 0.1 A
Operation Al Current At 17 V Minimum 5 Ma
Continuous Current Of The Diazed Fuse Link Of The Output
Relay4 A

Conducted Interference

Due To Burst According To Iec 61000-4-4 2 Kv
Due To Conductor-Earth Surge According To Iec 61000-4-5 2 Kv
Due To Conductor-Conductor Surge According To Iec
61000-4-51 Kv
Field-Based Interference According To Iec 61000-4-3 10 V/M
Electrostatic Discharge According To Iec 61000-4-2 6 Kv Contact Discharge / 8 Kv Air Discharge
Galvanic Isolation
Galvanic Isolation
Between Input And Output Yes
Between The Outputs Yes
Between The Voltage Supply And Other Circuits Yes
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip20

Connections/ Terminals

Product Component Removable Terminal For Auxiliary And
Control Circuityes
Type Of Electrical Connection Spring-Loaded Terminals
Type Of Connectable Conductor Cross-Sections
Solid 2X (0.25 ... 1.5 Mm²)
Finely Stranded With Core End Processing 2 X (0.25 ... 1.5 Mm²)
Finely Stranded Without Core End Processing 2X (0.25 ... 1.5 Mm²)
For Awg Cables Solid 2X (24 ... 16)
For Awg Cables Stranded 2X (24 ... 16)
Connectable Conductor Cross-Section
Solid 0.25 ... 1.5 Mm²
Finely Stranded With Core End Processing 0.25 ... 1.5 Mm²
Finely Stranded Without Core End Processing 0.25 ... 1.5 Mm²
Awg Number As Coded Connectable Conductor Cross
Section
Solid 24 ... 16
Stranded 24 ... 16
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Snap-On Mounting
Height 94 Mm
Width 22.5 Mm
Depth 91 Mm
Required Spacing
With Side-By-Side Mounting
— Forwards 0 Mm
— Backwards 0 Mm
— Upwards 0 Mm
— Downwards 0 Mm
— At The Side 0 Mm
For Grounded Parts
— Forwards 0 Mm
— Backwards 0 Mm
— Upwards 0 Mm
— At The Side 0 Mm
— Downwards 0 Mm
For Live Parts
— Forwards 0 Mm
— Backwards 0 Mm
— Upwards 0 Mm
— Downwards 0 Mm
— At The Side 0 Mm

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -25 ... +60 °C
During Storage -40 ... +85 °C
During Transport -40 ... +85 °C
Environmental Footprint
Global Warming Potential [Co2 Eq] Total 16.1 Kg
Global Warming Potential [Co2 Eq] During Manufacturing 3.51 Kg
Global Warming Potential [Co2 Eq] During Operation 13.7 Kg