Description for 3SE5312-2SD12 Siemens

3SE5312-2SD12 Siemens - Safety position switch with tumbler Locking force 2600 N 5 directions of approaches Spring-locked Auxiliary release on front Magnet voltage 115 V AC Monitoring actuator 2 NC/1 NO Monitoring magnet 2 NC/1 NO LED display yellow/green Supplied without actuator. Actuator 3SE5000-0AV0. please order separately

Free Delivery to UK Mainland on orders over £25

Manufacturer New

1 available
5 - 8 w.days
£240.94 Exc. VAT
£289.13 Inc. VAT

Direct from Manufacturer

Fetching stock
2 - 3 W.Weeks

£174.92 Exc. VAT
£209.90 Inc. VAT

General Technical Data

Product Function Positive Opening Yes
Locking Force 2 600 N
According To En Iso 14119 2 000 N
Insulation Voltage Rated Value 250 V
Degree Of Pollution Class 3
Surge Voltage Resistance Rated Value 4 Kv
Shock Resistance 30G / 11 Ms
According To Iec 60068-2-27 30G / 11 Ms
Vibration Resistance 0.35 Mm / 5G
According To Iec 60068-2-6 0.35 Mm/5G
Mechanical Service Life (Operating Cycles) Typical 1 000 000
Thermal Current 10 A
Material Of The Enclosure Of The Switch Head Metal
Reference Code According To Iec 81346-2 B
Continuous Current Of The C Characteristic Mcb 1 A; For A Short-Circuit Current Smaller Than 400 A
Continuous Current Of The Quick Diazed Fuse Link 10 A; For A Short-Circuit Current Smaller Than 400 A
Continuous Current Of The Diazed Fuse Link Gg 6 A; For A Short-Circuit Current Smaller Than 400 A
Repeat Accuracy 0.05 Mm
Substance Prohibitance (Date) 10/01/2011
Svhc Substance Name Lead - 7439-92-1
Lead Monoxide (Lead Oxide) - 1317-36-8
Weight 0.975 Kg
Minimum Actuating Force In Directions Of Actuation 30 N
Length Of The Sensor 185 Mm
Width Of The Sensor 54 Mm

Ambient Conditions

Ambient Temperature
During Operation -25 ... +60 °C
During Storage -40 ... +80 °C
Explosion Protection Category For Dust None
Consumed Active Power Of Magnet Coil 4.5 W
Operation Al Current At Ac-15
At 24 V Rated Value 6 A
At 120 V Rated Value 6 A
At 240 V Rated Value 3 A
Operation Al Current At Dc-13
At 24 V Rated Value 3 A
At 125 V Rated Value 0.55 A
At 250 V Rated Value 0.27 A
Enclosure
Design Of The Housing Special Design
Material Of The Enclosure Metal
Coating Of The Enclosure Cathodic Dip Coating
Design Of The Housing According To Standard No
Locking Mechanism Design Spring-Actuated Lock (Closed-Circuit Principle) With Auxiliary Release
Drive Head
Design Of The Actuating Element 5 Directions Of Approach
Design Of The Switching Function Positive Opening
Number Of Directions Of Actuation 5
Circuit Principle Slow-Action Contacts
Number Of Switching Contacts Safety-Related 4
Cable Entry Type 3X (M20 X 1.5)
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Screw Fixing

Connections/ Terminals

Type Of Electrical Connection Screw Terminal
Type Of Connectable Conductor Cross-Sections
Solid 1X (0.5 ... 1.5 Mm²), 2X (0.5 ... 0.75 Mm²)
Finely Stranded With Core End Processing 1X (0.5 ... 1.5 Mm²), 2X (0.5 ... 0.75 Mm²)
For Awg Cables Solid 1X (20 ... 16), 2X (20 ... 18)
For Awg Cables Stranded 1X (20 ... 16), 2X (20 ... 18)

Supply Voltage

Type Of Voltage Of The Supply Voltage Of The Optional Led Display Ac
Supply Voltage Of Led
115 V
Supply Voltage Of Magnet Coil 115 V
Design Of The Interface For Safety-Related Communication Without

Communication/ Protocol

Design Of The Interface Without

Safety Related Data

Proportion Of Dangerous Failures With High Demand Rate
According To Sn 3192020 %
B10 Value With High Demand Rate According To Sn 31920 1 000 000