Siemens

3RW3018-2BB04

3RW3018-2BB04 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RW3018-2BB04 Siemens

3RW3018-2BB04 Siemens - SOFTSTART, 17A, 3/3/10HP, 24V, SPRNG

Extended Description for 3RW3018-2BB04 Siemens

3RW3018-2BB04 Siemens - SIRIUS soft starter s00 17.6 a, 7.5 KW/400 V, 40 ¦c 200-480 V AC, 24 V AC/DC spring-type terminals

Free Delivery to UK Mainland on orders over £25

Manufacturer New

Available for Back Order
£297.95 Exc. VAT
£357.54 Inc. VAT

Manufacturer New

17 available
5 - 8 w.days
£303.17 Exc. VAT
£363.80 Inc. VAT

Direct from Manufacturer

Fetching stock
2 - 3 W.Weeks

£217.93 Exc. VAT
£261.51 Inc. VAT

Product

Article Number (Market Facing Number) 3RW3018-2BB04
Product Description SIRIUS soft starter S00 17.6 A, 7.5 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Spring-type terminals
Product family 3RW30 soft starters
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 0,466 Kg
Packaging Dimension 123,00 x 162,00 x 60,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209719743
UPC 754554958217
Commodity Code 85371098
LKZ_FDB/ CatalogID CC-IC10
Product Group 5345
Group Code R711
Country of origin Czech Republic
Compliance with the substance restrictions according to RoHS directive Since: 01.07.2006
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Product Brand Name Sirius
Product Designation Soft Starter
Product Feature
Integrated Bypass Contact System Yes
Thyristors Yes

Product Function

Intrinsic Device Protection No
Motor Overload Protection No
Evaluation Of Thermistor Motor Protection No
External Reset No
Adjustable Current Limitation No
Inside-Delta Circuit No
Product Component Motor Brake Output No
Insulation Voltage Rated Value V 600
Degree Of Pollution 3, Acc. To Iec 60947-4-2
Blocking Voltage Of The Thyristor Maximum V 1 200
Reference Code According To En 61346-2 Q
Reference Code According To Din 40719 Extended According
To Iec 204-2 According To Iec 750G
Power Electronics
Operation Al Current
At 40 °C Rated Value A 17.6
At 50 °C Rated Value A 17
At 60 °C Rated Value A 14
Yielded Mechanical Performance For 3-Phase Motors
At 230 V
— At Standard Circuit At 40 °C Rated Value Kw 4
At 400 V
— At Standard Circuit At 40 °C Rated Value Kw 7.5
Yielded Mechanical Performance [Hp] For 3-Phase Ac Motor
At 200/208 V At Standard Circuit At 50 °C Rated Valuehp 3
Operating Frequency Rated Value Hz 50 ... 60
Relative Negative Tolerance Of The Operating Frequency % -10
Relative Positive Tolerance Of The Operating Frequency % 10
Operating Voltage At Standard Circuit Rated Value V 200 ... 480
Relative Negative Tolerance Of The Operating Voltage At
Standard Circuit% -15
Relative Positive Tolerance Of The Operating Voltage At
Standard Circuit% 10
Minimum Load [%] % 10
Continuous Operating Current [% Of Ie] At 40 °C % 115
Power Loss [W] At Operational Current At 40 °C During
Operation Typicalw 4
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Ac/Dc
Control Supply Voltage Frequency 1 Rated Value Hz 50
Control Supply Voltage Frequency 2 Rated Value Hz 60
Relative Negative Tolerance Of The Control Supply Voltage
Frequency% -10
Relative Positive Tolerance Of The Control Supply Voltage
Frequency% 10
Control Supply Voltage 1 At Ac
At 50 Hz Rated Value V 24
At 60 Hz Rated Value V 24
Relative Negative Tolerance Of The Control Supply Voltage At
Ac At 50 Hz% -15
Relative Positive Tolerance Of The Control Supply Voltage At
Ac At 50 Hz% 10
Relative Negative Tolerance Of The Control Supply Voltage At
Ac At 60 Hz% -15
Relative Positive Tolerance Of The Control Supply Voltage At
Ac At 60 Hz% 10
Control Supply Voltage 1 At Dc Rated Value V 24
Relative Negative Tolerance Of The Control Supply Voltage At
Dc% -20
Relative Positive Tolerance Of The Control Supply Voltage At
Dc% 20
Display Version For Fault Signal Red

Mechanical Data

Size Of Engine Control Device S00
Width Mm 45
Height Mm 120
Depth Mm 150
Fastening Method Screw And Snap-On Mounting
Mounting Position With Vertical Mounting Surface +/-10° Rotatable, With Vertical
Mounting Surface +/- 10° Tiltable To The Front And Back
Required Spacing With Side-By-Side Mounting
Upwards Mm 60
At The Side Mm 15
Downwards Mm 40
Wire Length Maximum M 300
Number Of Poles For Main Current Circuit 3

Connections/ Terminals

Type Of Electrical Connection
For Main Current Circuit Spring-Loaded Terminals
For Auxiliary And Control Circuit Spring-Loaded Terminals
Number Of Nc Contacts For Auxiliary Contacts 0
Number Of No Contacts For Auxiliary Contacts 1
Number Of Co Contacts For Auxiliary Contacts 0
Type Of Connectable Conductor Cross-Sections For Main
Contacts For Box Terminal Using The Front Clamping Point
Solid 2X (1 ... 2.5 Mm²), 2X (2.5 ... 6 Mm²)
Finely Stranded With Core End Processing 2X (1 ... 2.5 Mm²), 2X (2.5 ... 6 Mm²)
Type Of Connectable Conductor Cross-Sections For Awg
Cables For Main Contacts For Box Terminal
Using The Front Clamping Point 2X (16 ... 10)
Type Of Connectable Conductor Cross-Sections For Main
Contacts
Solid 1 ... 4 Mm²
Finely Stranded With Core End Processing 1 ... 2.5 Mm²
Type Of Connectable Conductor Cross-Sections For Auxiliary
Contacts
Solid 2X (0.25 ... 2.5 Mm²)
Finely Stranded With Core End Processing 2X (0.25 ... 1.5 Mm²)
Type Of Connectable Conductor Cross-Sections For Awg
Cables
For Main Contacts 16 ... 12
For Auxiliary Contacts 2X (24 ... 14)

Ambient Conditions

Installation Altitude At Height Above Sea Level M 5 000
Environmental Category
During Transport According To Iec 60721 2K2, 2C1, 2S1, 2M2 (Max. Fall Height 0.3 M)
During Storage According To Iec 60721 1K6 (Only Occasional Condensation), 1C2 (No Salt Mist), 1S2
(Sand Must Not Get Inside The Devices), 1M4
During Operation According To Iec 60721 3K6 (No Formation Of Ice, No Condensation), 3C3 (No Salt Mist),
3S2 (Sand Must Not Get Into The Devices), 3M6
Ambient Temperature
During Operation °C -25 ... +60
During Storage °C -40 ... +80
Derating Temperature °C 40
Protection Class Ip On The Front According To Iec 60529 Ip20
Touch Protection On The Front According To Iec 60529 Finger-Safe, For Vertical Contact From The Front
Environmental Footprint
Global Warming Potential [Co2 Eq] Total Kg 63.9
Global Warming Potential [Co2 Eq] During Manufacturing Kg 11.1
Global Warming Potential [Co2 Eq] During Sales Kg 0.109
Global Warming Potential [Co2 Eq] During Operation Kg 54.3
Global Warming Potential [Co2 Eq] After End Of Life Kg -1.64
Ul/Csa Ratings
Yielded Mechanical Performance [Hp] For 3-Phase Ac Motor
At 220/230 V
— At Standard Circuit At 50 °C Rated Value Hp 3
At 460/480 V
— At Standard Circuit At 50 °C Rated Value Hp 10
Contact Rating Of Auxiliary Contacts According To Ul B300 / R300