Siemens

3RB3016-1SB0

3RB3016-1SB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RB3016-1SB0 Siemens

3RB3016-1SB0 Siemens - OVERLOAD S.S. CL10 S00 3-12A SCREW

Extended Description for 3RB3016-1SB0 Siemens

3RB3016-1SB0 Siemens - Overload relay 3...12 a for motor protection size s00, class 10 contactor ass. main circuit screw conn. aux.circuit screw conn. manual-autom.-reset

Free Delivery to UK Mainland on orders over £25

Manufacturer New

7 available
1 - 2 w.days
£75.09 Exc. VAT
£90.11 Inc. VAT

Manufacturer New

Available for Back Order
£111.38 Exc. VAT
£133.66 Inc. VAT

Manufacturer New

8 available
5 - 8 w.days
£109.42 Exc. VAT
£131.31 Inc. VAT

Direct from Manufacturer

Fetching stock
2 - 3 W.Weeks

£43.24 Exc. VAT
£51.89 Inc. VAT

Product

Article Number (Market Facing Number) 3RB3016-1SB0
Product Description Overload relay 3...12 A Electronic For motor protection Size S00, Class 10E Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset
Product family SIRIUS 3RB electronic overload relays
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 0,223 Kg
Packaging Dimension 87,00 x 97,00 x 56,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209748644
UPC 662643904970
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5350
Group Code R711
Country of origin Czech Republic
Compliance with the substance restrictions according to RoHS directive Since: 01.10.2009
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Size Of Overload Relay S00
Size Of Contactor Can Be Combined Company-Specific S00
Power Loss [W] For Rated Value Of The Current At Ac In Hot
Operating State0.6 W
Per Pole 0.2 W
Insulation Voltage With Degree Of Pollution 3 At Ac Rated Value 690 V
Surge Voltage Resistance Rated Value 6 Kv
Maximum Permissible Voltage For Protective Separation
In Networks With Ungrounded Star Point Between Auxiliary
And Auxiliary Circuit300 V
In Networks With Grounded Star Point Between Auxiliary
And Auxiliary Circuit300 V
In Networks With Ungrounded Star Point Between Main And
Auxiliary Circuit600 V
In Networks With Grounded Star Point Between Main And
Auxiliary Circuit690 V
Shock Resistance 15G / 11 Ms
According To Iec 60068-2-27 15G / 11 Ms; Signaling Contact 97 / 98 In Position "Tripped": 9G / 11 Ms
Vibration Resistance 1-6 Hz, 15 Mm; 6-500 Hz, 20 M/S²; 10 Cycles
Thermal Current 12 A
Recovery Time After Overload Trip
With Automatic Reset Typical 3 Min
With Remote-Reset 0 Min
With Manual Reset 0 Min
Reference Code According To Iec 81346-2 F
Substance Prohibitance (Date) 10/01/2009
Svhc Substance Name Lead Monoxide (Lead Oxide) - 1317-36-8
Weight 0.223 Kg

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -25 ... +60 °C
During Storage -40 ... +80 °C
During Transport -40 ... +80 °C
Temperature Compensation -25 ... +60 °C
Relative Humidity During Operation 10 ... 95 %

Main Circuit

Number Of Poles For Main Current Circuit 3
Adjustable Current Response Value Current Of The Current-
Dependent Overload Release3 ... 12 A
Operating Voltage
Rated Value 690 V
At Ac-3E Rated Value Maximum 690 V
Operating Frequency Rated Value 50 ... 60 Hz
Operation Al Current Rated Value 12 A
Operation Al Current At Ac-3E At 400 V Rated Value 12 A
Operating Power
For 3-Phase Motors At 400 V At 50 Hz 1.5 ... 5.5 Kw
For Ac Motors At 500 V At 50 Hz 1.5 ... 5.5 Kw
For Ac Motors At 690 V At 50 Hz 2.2 ... 7.5 Kw
Auxiliary Circuit
Design Of The Auxiliary Switch Integrated
Number Of Nc Contacts For Auxiliary Contacts 1
Note For Contactor Disconnection
Number Of No Contacts For Auxiliary Contacts 1
Note For Message "Tripped"
Number Of Co Contacts For Auxiliary Contacts 0
Operation Al Current Of Auxiliary Contacts At Ac-15
At 24 V 4 A
At 110 V 4 A
At 120 V 4 A
At 125 V 4 A
At 230 V 3 A
Operation Al Current Of Auxiliary Contacts At Dc-13
At 24 V 2 A
At 60 V 0.55 A
At 110 V 0.3 A
At 125 V 0.3 A
At 220 V 0.11 A
Protective And Monitoring Functions
Trip Class Class 10E
Design Of The Overload Release Electronic
Ul/Csa Ratings
Full-Load Current (Fla) For 3-Phase Ac Motor
At 480 V Rated Value 12 A
At 600 V Rated Value 12 A
Contact Rating Of Auxiliary Contacts According To Ul B600 / R300
Short-Circuit Protection
Design Of The Fuse Link
For Short-Circuit Protection Of The Main Circuit
— With Type Of Coordination 1 Required Gg: 50 A, Rk5: 45 A
— With Type Of Assignment 2 Required Gg: 50 A, J: 45 A
For Short-Circuit Protection Of The Auxiliary Switch Required Fuse Gg: 6 A
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Contactor Mounting
Height 79 Mm
Width 45 Mm
Depth 73 Mm

Connections/ Terminals

Product Component Removable Terminal For Auxiliary And
Control Circuityes
Type Of Electrical Connection
For Main Current Circuit Screw-Type Terminals
For Auxiliary And Control Circuit Screw-Type Terminals
Arrangement Of Electrical Connectors For Main Current
Circuittop And Bottom
Type Of Connectable Conductor Cross-Sections For Main Contacts
Solid 1X (0.5 ... 4 Mm²), 2X (0.5 ... 1.5 Mm²), 2X (0.75 ... 4 Mm²)
Solid Or Stranded 1X (0,5 ... 4 Mm²), 2X (0,5 ... 1,5 Mm²), 2X (0,75 ... 4 Mm²)
Finely Stranded With Core End Processing 1X (0.5 ... 2.5 Mm²), 2X (0.5 ... 2.5 Mm²)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
— Solid 1X (0.5 ... 4 Mm²), 2X (0.5 ... 2.5 Mm²)
— Solid Or Stranded 1X (0,5 ... 4 Mm²), 2X (0,5 ... 2,5 Mm²)
— Finely Stranded With Core End Processing 1X (0.5 ... 2.5 Mm²), 2X (0.5 ... 1.5 Mm²)
For Awg Cables For Auxiliary Contacts 1X (20 ... 14), 2X (20 ... 14)
Tightening Torque
For Main Contacts With Screw-Type Terminals 0.8 ... 1.2 N·M
For Auxiliary Contacts With Screw-Type Terminals 0.8 ... 1.2 N·M
Design Of Screwdriver Shaft Diameter 5 To 6 Mm
Size Of The Screwdriver Tip Pozidriv Pz 2
Design Of The Thread Of The Connection Screw
For Main Contacts M3
Of The Auxiliary And Control Contacts M3
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip20
Touch Protection On The Front According To Iec 60529 Finger-Safe, For Vertical Contact From The Front

Communication/ Protocol

Type Of Voltage Supply Via Input/Output Link Master No

Conducted Interference

Due To Burst According To Iec 61000-4-4 2 Kv (Power Ports), 1 Kv (Signal Ports) Corresponds To Degree Of Severity 3
Due To Conductor-Earth Surge According To Iec 61000-4-5 2 Kv (Line To Earth) Corresponds To Degree Of Severity 3
Due To Conductor-Conductor Surge According To Iec
61000-4-51 Kv (Line To Line) Corresponds To Degree Of Severity 3
Due To High-Frequency Radiation According To Iec 61000-
4-610 V In Frequency Range 0.15 To 80 Mhz, Modulation 80 % Am With 1 Khz
Field-Based Interference According To Iec 61000-4-3 10 V/M
Electrostatic Discharge According To Iec 61000-4-2 6 Kv Contact Discharge / 8 Kv Air Discharge
Display
Display Version For Switching Status Slide Switch

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible