3NP1133-1BC10 Siemens - SW DISC 3NP 160A FLT TRML SZ00 60BUS ALL

Extended Description for 3NP1133-1BC10 Siemens

3NP1133-1BC10 Siemens - SIEMENS LOW VOLTAGE FUSE SWITCH DISCONNECTOR 3NP FOR BUSBAR MOUNTING. 160A 3-POLE SWITCH WITH FLAT TERMINAL CONNECTOR. SUITS NH FUSES SIZE 00. WITH REACH-AROUND PROTECTION SUITABLE FOR SIEMENS 8US, WOHNER CLASSIC, AND RITAL RiLine60 60MM BUSBAR SYSTEMS WITHOUT BASE.

Free Delivery to UK Mainland on orders over £25

Manufacturer New

2 available
2 - 5 w.days
£100.43 Exc. VAT
£120.52 Inc. VAT

Manufacturer New

Available for Back Order
£152.29 Exc. VAT
£182.75 Inc. VAT

Manufacturer New

Available for Back Order
£81.58 Exc. VAT
£97.90 Inc. VAT

Direct from Manufacturer

Fetching stock
2 - 3 W.Weeks

£52.89 Exc. VAT
£63.47 Inc. VAT

Product

Article Number (Market Facing Number) 3NP1133-1BC10
Product Description SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for Busbar system 8US 60 mm, flat terminal, Cover level 32/70 mm
Product family SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 1,095 Kg
Packaging Dimension 118,00 x 230,00 x 159,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209700284
UPC 662643545135
Commodity Code 85365080
LKZ_FDB/ CatalogID LV10.1
Product Group 5863
Group Code P360
Country of origin Czech Republic
Compliance with the substance restrictions according to RoHS directive Since: 23.10.2008
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Model

Product Designation Fuse Switch Disconnector
Busbar Design Busbar Thickness 5 Or 10 Mm
Design Of The Safety Monitoring Without
Design Of The Load Switch Strip Form No
Type Of The Driving Mechanism Motor Drive No

General Technical Data

Number Of Poles 3
Type Of Device For 60 Mm 8Us Busbar System
Size Of Disconnecting Link 00 And 000
Size Of Fuse Link Nh000, Nh00
Let-Through Current With Closed Switch Maximum 23 Ka
Mechanical Service Life (Operating Cycles) Typical 2 000
I2T Value With Closed Switch Maximum 223 Ka2.S
Power Factor
At Ac-22 B 0.65
At Ac-23 B 0.45
With Capacitive Load -0.25
Fuse System Lv Hrc Fuse
Degree Of Pollution 3

Voltage

Insulation Voltage
Rated Value 690 V
With Degree Of Pollution 3 At Ac Rated Value 690 V
With Degree Of Pollution 2 At Ac Rated Value 1 000 V
Power Factor At Ac-21 B 0.95
Surge Voltage Resistance Rated Value 8 Kv
Operation Al Current
At 35 °C Rated Value 160 A
At 40 °C Rated Value 155 A
At 45 °C Rated Value 145 A
At 50 °C Rated Value 140 A
At 55 °C Rated Value 133 A
At Ac-21 B At 240 V Rated Value 160 A
At Ac-21 B At 400 V Rated Value 160 A
At Ac-21 B At 500 V Rated Value 160 A
At Ac-21 B At 690 V Rated Value 160 A
At Ac-22 B At 240 V Rated Value 160 A
At Ac-22 B At 400 V Rated Value 160 A
At Ac-22 B At 500 V Rated Value 160 A
At Ac-22 B At 690 V Rated Value 125 A
At Ac-23 B At 690 V Rated Value 35 A
At Ac-23 B At 500 V Rated Value 63 A
At Ac-23 B At 400 V Rated Value 160 A
At Ac-23 B At 240 V Rated Value 160 A
At Dc-21 B At 120 V Rated Value 160 A
At Dc-21 B At 240 V Rated Value 160 A
At Dc-21 B At 440 V Rated Value 160 A
At Dc-22 B At 120 V Rated Value 160 A
At Dc-22 B At 240 V Rated Value 160 A
At Dc-22 B At 440 V Rated Value 125 A
At Dc-23 B At 120 V Rated Value 100 A
At Dc-23 B At 240 V Rated Value 100 A
At Dc-23 B At 440 V Rated Value 63 A
Let-Through Current With High-Speed Activation Maximum
Permissible15 Ka
Operating Voltage
At Ac Rated Value Maximum 690 V
At Dc Rated Value 440 V
At Dc Rated Value Maximum 440 V

Protection Class

Protection Class Ip
With Closed Switch With Cover Or Cable Lug Cover Ip40
With Closed Switch Without Cover Or Cable Lug Cover Ip30
Open Ip20

Dissipation

Power Loss [W]
With Conventional Rated Thermal Current Without Fuse Per
Pole5 W
With Conventional Rated Thermal Current Without Fuse Per
Device15 W
For Rated Value Of The Current At Ac In Hot Operating State
Per Pole17 W
Of The Fuse Per Fuse Maximum 12 W

Main Circuit

Operation Al Current
Rated Value 160 A
With Capacitive Load At 400 V Rated Value 72 A
With Capacitive Load At 500 V Rated Value 55 A

Auxiliary Circuit

Number Of Co Contacts For Auxiliary Contacts 0
Number Of Nc Contacts For Auxiliary Contacts 0
Number Of No Contacts For Auxiliary Contacts 0
Suitability
Suitability For Use
Main Switch No
Switch Disconnector Yes
Emergency Off Switch No
Safety Switch Yes
Maintenance/Repair Switch Yes

Product Details

Product Function Phase Failure Monitoring No

Product Component

Undervoltage Release No
Undervoltage Release With Leading Contact No
Product Feature Sealable Yes
Product Extension Auxiliary Switch Yes
Product Extension Optional
Locking Capability Yes
Phase Failure Monitoring Yes
Fuse Monitoring Yes
Voltage Trigger No
Overvoltage Protection Monitoring Yes

Product Function

Product Function Overvoltage Protection Monitoring No
Short Circuit
Conditional Short-Circuit Current (Iq)
At Ac At 240 V With High-Speed Activation Rated Value 80 Ka
At Ac At 500 V With High-Speed Activation Rated Value 80 Ka
At Ac At 690 V With High-Speed Activation Rated Value 50 Ka
With Closed Switch At Ac At 240 V Rated Value 120 Ka
With Closed Switch At Ac At 500 V Rated Value 120 Ka
With Closed Switch At Ac At 690 V Rated Value 100 Ka

Connections

Arrangement Of Electrical Connectors For Main Current Circuit Other
Connectable Conductor Cross-Section For Main Contacts
Solid Or Stranded Minimum 2.5 Mm²
Solid Or Stranded Maximum 95 Mm²
Stranded Minimum 2.5 Mm²
Stranded Maximum 95 Mm²

Tightening Torque With Screw-Type Terminals

Minimum 10 N·M
Maximum 12 N·M
Type Of Connectable Conductor Cross-Sections Of The Laminated
Conductors Maximum24 X 12 Mm
Type Of Connection Technology Flat Terminal

Mechanical Design

Height 206.2 Mm
Width 105.8 Mm
Width Of The Busbar
Minimum 12 Mm
Maximum 30 Mm
Depth 137.5 Mm
Fastening Method Busbar
Fastening Method
Floor Mounting No
Rail Mounting Yes
Mounting Position Horizontal/Vertical
Busbar Center-To-Center Spacing 60 Mm
Net Weight 0.98 Kg

Ambient Temperature During Operation

Minimum -25 °C
Maximum 55 °C

Ambient Temperature During Storage

Minimum -50 °C
Maximum 80 °C
Certificates