VPL06N Schneider Electric - Power Factor controller - VarPlus Logic - VPL 6

Extended Description for VPL06N Schneider Electric

VPL06N Schneider Electric - VarPlus logic is a simple and efficient Power Controller for a automatic power factor correction equipment to maintain the power factor.,It is a simple and intelligent relay which measures,monitor and Controls the reactive energy.,It comes with Easy Commisioning , Step Size detection and monitoring along with the variour alarms.,VPL06 can be used for 6 steps in a PFC equippment

Free Delivery to UK Mainland on orders over £25

Manufacturer New

10 available
5 - 8 w.days
£991.66 Exc. VAT
£1,189.99 Inc. VAT

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£246.42 Exc. VAT
£295.70 Inc. VAT

Main

Range PowerLogic
Product name PowerLogic PFC Controller
Device short name VPL6
product or component type Power factor controller

Complementary

Number of step output contacts 6
[Us] rated supply voltage 90...550 V AC,<= 999 kV AC with external VT
Measurement current 0…5 A
Measurement voltage 90…550 V AC 50/60 Hz
Operating mode Manual or automatic
Number of quadrant operation for generator application 4
Device connection Communication protocol: Modbus interface: RS485
Input function Switch: 1 x dry contact
Colour code Front: dark grey RAL 7016
Display type Backlit LCD
Display size 56 x 25 mm
Function available Automatic detection,Advanced programming (expert),Manual programming,Any step sequence,Automatic initialisation
Metering type Power factor and displacement PF (signed, four quadrant),Total current harmonic distortion THD (I),Power factor average over lifetime,Temperature maximum,Phase current I1, I2, I3 RMS on load,Active power P, P1, P2, P3 on load,Reactive power Q, Q1, Q2, Q3 on load,Apparent power S, S1, S2, S3 on load,Voltage U21, U32, U13, V1, V2, V3 on load
Type of measurement Ambient temperature inside the cubicle,Tan φ,Individual voltage harmonic,Cos φ,Operating time,Power factor,Capacitor current overload Irms/I1
Information displayed Number of switching cycles per step,Remaining step capacity in %,Individual step size in kVAr
Type of alarms Step power loss (< 75 %) / Action: message and alarm contact + step blocked,Step faulty / Action: message and alarm contact + step blocked,High current (> 6 A CT) / Action: message and alarm contact,Hunting (unstable regulation) / Action: message and alarm contact + step blocked,Low current (< 15 mA CT) / Action: message and alarm contact,Overcompensation / Action: message and alarm contact,Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off,Overtemperature (50 °C) / Action: message and alarm contact + step switched off,Overtemperature (30 °C) / Action: fan switch,Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped,Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
Data recording 5 alarms
Operational Hours alarm 100000 h without maintenance
Operational counter alarm 65000 cycles without maintenance
input type Insensitive to phase rotation polarity,Insensitive to CT polarity,Phase to neutral,Current input CT...X/5 A and X/1 A,Phase to phase
Output type Control relay: 0.2 A 110 V DC,Control relay: 1 A 48 V DC,Control relay: 2 A 400 V AC 50/60 Hz,Control relay: 1 A 24 V DC,Control relay: 5 A 250 V AC 50/60 Hz,Control relay: 5 A 120 V AC 50/60 Hz,Fan: 5 A 250 V AC 50/60 Hz,Fan: 1 A 48 V DC,Alarm relay: 5 A 250 V AC 50/60 Hz,Alarm relay: 1 A 48 V DC
Maximum at the common terminal 10 A
settings operating mode Manual,Automatic
Type of setting Choice of stepping programs: auto,Choice of stepping programs: LIFO,Choice of stepping programs: linear,Delay between 2 successive switch on the same step: 5...1200 s,Step configuration programming: auto,Step configuration programming: off,Step configuration programming: fixed,Target cos phi: 0.7 inductive...0.7 capacitive,Target cos phi: dual cos φ
Measurement accuracy Voltage +/- 1 %,Current +/- 1 %,Frequency +/- 1 %,Energy (P,Q,S) +/- 2 %,Cos φ +/- 2 %,Total voltage harmonic distortion THD (U) +/- 2 %,Individual voltage harmonic +/- 3 %,Temperature +/- 3 °C
Time delay range 1...6500 s (on reconnection),1...6500 s (on response)
Provided equipment User manual
mounting mode Flush-mounted
Mounting support Panel - thickness: 1…3 mm
Mounting location In cabinet
cut-out dimensions 138 x 138 mm
Height 144 mm
Width 144 mm
Depth 58 mm
net weight 0.6 kg

Environment

Standards IEC 61000-6-2,EN 61010-1,IEC 61000-6-4,IEC 61326-1,UL 61010-1
Product certifications EAC,NRTL,cNRTL,CE
IP degree of protection Front face: IP41,Rear face: IP20
Operating altitude <= 2000 m
Ambient air temperature for operation -20…60 °C
Ambient air temperature for storage -40…85 °C

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.200 cm
Package 1 Width 17.800 cm
Package 1 Length 18.400 cm
Package 1 Weight 696.000 g
Unit Type of Package 2 S03
Number of Units in Package 2 8
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 6.050 kg
Unit Type of Package 3 P06
Number of Units in Package 3 64
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 60.348 kg

Contractual warranty

Warranty 18 months