Schneider Electric

RM22TR31

RM22TR31 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for RM22TR31 Schneider Electric

RM22TR31 Schneider Electric - 3-phase control relay, Harmony Control Relays, 8A, 2CO, overvoltage and undervoltage detection, 200…240V AC

Extended Description for RM22TR31 Schneider Electric

RM22TR31 Schneider Electric - 3-phase control relay, Harmony Control Relays, 8A, 2CO, overvoltage and undervoltage detection, 200…240V AC

Free Delivery to UK Mainland on orders over £25

Manufacturer New

13 available
1 - 2 w.days
£116.06 Exc. VAT
£139.27 Inc. VAT

Manufacturer New

1 available
5 - 8 w.days
£166.51 Exc. VAT
£199.81 Inc. VAT

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£59.66 Exc. VAT
£71.59 Inc. VAT

Main

range of product Harmony Control Relays
Relay type Control relay
product or component type 3-phase control relay
Network number of phases 3 phases
Relay name RM22TR
Relay monitored parameters Phase sequence,Phase failure detection,Overvoltage and undervoltage detection
Time delay type Adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault
Switching capacity in VA 2000 VA
Measurement range 200...240 V voltage AC
Contacts type and composition 2 C/O

Complementary

Reset time 1500 ms at maximum voltage
Maximum switching voltage 250 V AC
Minimum switching current 10 mA at 5 V DC
Maximum switching current 8 A AC
[Us] rated supply voltage AC/DC
Supply voltage limits 160…288 V AC
operating limits - 20 % + 20 % Un
Power consumption in VA 10 VA at 240 V AC 60 Hz
Voltage detection threshold < 100 V AC
supply voltage frequency 50...60 Hz +/- 10 %
Output contacts 2 C/O
Setting accuracy of the switching threshold +/- 10 % of the full scale
Switching threshold drift <= 0.05 % per degree centigrade depending permissible ambient air temperature,<= 1 % within the supply voltage range
Setting accuracy of time delay 10 P
Time delay drift <= 0.05 % per degree centigrade depending permissible ambient air temperature,<= 1 % within the supply voltage range
Hysteresis 2 % fixed of selectable
Run-up delay at power-up 650 ms
Maximum measuring cycle 150 ms measurement cycle as true rms value
Threshold adjustment voltage 2...20 % of Un selected
Voltage range 200...240 V phase to phase
Repeat accuracy +/- 0.5 % for input and measurement circuit,+/- 3 % for time delay
Measurement error < 1 % over the whole range with voltage variation,< 0.05 %/°C with temperature variation
Response time <= 300 ms
Overvoltage category III conforming to IEC 60664-1,III conforming to UL 508
Insulation resistance > 100 MOhm at 500 V DC conforming to IEC 60255-27
Mounting position Any position
Connections - terminals Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end,Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end,Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end,Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Tightening torque 0.6…1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing plastic
Status LED LED (yellow) relay ON,LED (green) power ON
Mounting support 35 mm DIN rail conforming to IEC 60715
Electrical durability 100000 cycles
Mechanical durability 10000000 cycles
Utilisation category AC-15 conforming to IEC 60947-5-1,DC-13 conforming to IEC 60947-5-1,AC-1 conforming to IEC 60947-4-1,DC-1 conforming to IEC 60947-4-1
[Un] rated nominal voltage , self-powered
Safety reliability data MTTFd = 388.1 years,B10d = 350000
Contacts material Cadmium free
Control type With test button
Width 22.5 mm
net weight 0.09 kg

Environment

Immunity to microbreaks 10 ms
Electromagnetic compatibility Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1,Immunity for industrial environments conforming to IEC 61000-6-2,Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3,Emission standard for industrial environments conforming to IEC 61000-6-4,Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2,Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2,Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3,Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4,Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4,Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5,Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5,Conducted and radiated emissions class B group 1 conforming to CISPR 11,Conducted and radiated emissions class B conforming to CISPR 22
Standards IEC 60255-1
Product certifications CSA,CCC,EAC,RCM,CE,GL,UL
Ambient air temperature for storage -40…70 °C
Ambient air temperature for operation -20…50 °C at 60 Hz,-20…60 °C at 50 Hz AC/DC
Relative humidity 93…97 % at 25…55 °C conforming to IEC 60068-2-30
Vibration resistance 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6,1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6,0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6,0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
Shock resistance 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27,5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
IP degree of protection IP20 (terminals) conforming to IEC 60529,IP40 (housing) conforming to IEC 60529,IP50 (front panel) conforming to IEC 60529
Pollution degree 3 conforming to IEC 60664-1,3 conforming to UL 508
Dielectric test voltage 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.2 cm
Package 1 Width 9.5 cm
Package 1 Length 2.6 cm
Package 1 Weight 101.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 40
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 4.495 kg
Unit Type of Package 3 PAL
Number of Units in Package 3 640
Package 3 Height 50.0 cm
Package 3 Width 60.0 cm
Package 3 Length 80.0 cm
Package 3 Weight 86.18 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible