-
0AB
- B&R
- B&R Automation
- Baco
- Balluff
- Banner
- Banner Engineering
- Bartec
- Basler
- Baumer
- Baumer Electric
- Baumer Hubner
- Baumüller
- Beckhoff
- Beghelli
- Beijer Electronics
- Belden
- Belimo
- Bently Nevada
- Bernstein
- Betaduct
- Boardman Transformers
- Bopla
- Bosch Rexroth
- Bourns
- Broadcom
- BTI
- BTicino
- Burgess
- Burkert
- Busch Jaeger - ABB
- Bussmann
CDEHIKLMPS- Salzer
- Santon
- Sanyo Denki
- Scan
- Schaffner
- Schmersal
- Schneider
- Schneider Electric
- Schrack
- Seagate
- Selet
- Semikron
- Seneca
- Sensopart
- SEW Eurodrive
- Sharp
- Siba
- Sick
- Siemens
- Siemens Burners
- Siemens Smart Infrastructure
- Sirena
- SKS Hirschmann Test & Measurement
- Smartscan
- SMC
- Socomec
- SolaHD
- Sontay
- Spectrum Controls
- Square D
- StarTech
- Staubli
- STEGO
- STMicroelectronics
- Sunon
- Supertouch
- Swissbit
TW -
- Circuit Breakers
- Relays
- Surge Protection
- Electric Motors
- Convertors
- Enclosures
- Sockets
- Low Voltage Components
- Robotics
- Motor Starter
- Other
- CPU Modules
- Push buttons
- Safety Switches
- Sensors
- Transformers
- Level Monitoring
- Distribution Block
- Terminal Blocks
- Motor Protection
- Industrial Safety Products
- Labelling
- Fuse Switch Disconnector
- Fuse
- Industrial Cables
- Isolator Switch
- Selector Switch
- Wire Terminals & Connectors
- Industrial Modules
- Industrial Enclosure,Door & Mounting Plates
- Industrial Spare Parts
- Cable Marker
- Busbar & Cable Ducts
- UPS Systems
- Contactors
- Siemens SIMATIC Range
- Electronic Module
- Power Unit
- Power Modules & Drives
- Operating Panels
- Industrial Switches
- Control Systems
- Industrial Handles
- Variable Frequency & Adjustable Speed Drives
- Drive Converters
- Servo Motor
- Industrial Gearbox Spares
- Planetary Gearbox
- Incremental Encoder
- Resistors
- Pressure Switches
- Ammeter
- Industrial Automation Software
- Crimp Terminals
- Industrial Sockets
- Power Supply
- Trunking
- DIN Rails
- Distance Measuring Device
- Industrial Beacons
- Potentiometer
- RCBO Circuit Breakers
- Distribution Board
- Actuators
- Circuit Protection
- Expansion Modules
- Ethernet Media
- Industrial Valves & Accessories
- Limit Switch
- Mounting Frames
- Servo Drives
- Control and Automation Board
- DIN Rail Mounting Device
- Meter Panel
- Industrial Key Switches
- Speed Controller
- Pilot Lights
- Stepper Motors
- Push-Pull Device
- Connection Products
- Low Voltage Product Spares
- Industrial Rating Plugs
- Interface Unit
- Stack Lighting
- Compact Cylinder
- Pressure Transmitter
- Ethernet Cables
- Line Differential & Distance Protection Device
- Tower Light
- Energy Meters
- Industrial Automation Mounting Kits
- Consumer Unit
- Junction Box
- Variable Frequency & Adjustable Speed Drivess
- Industrial Power Socket
- Encoders
- Load Switch
- Modular Tower Lights
- Contactor Relay & Protection Relays
- Power Contactor
- Distribution Panels
- Power Meter
- Pneumatic
- Brushless DC Motor
- Key-operated switch
- Pressure Regulator
- Cylinderical Gears
- Interior Fitting Systems
- Residual Current Device Block
- Proximity Sensor
- Terminal Markers
- Merging Unit
- Fault Recorder
- Overcurrent & Feed Protection Device
- Frequency Converters
- Load Monitoring Devices
- Thermal Overload
- Residual Current Monitors
- Control Stations
- Industrial Line Protection Device
- Solenoid Valve Connector
- Trapped Key Interlock
- Industrial Indicator Lights
- Motion controller
- Protective Relay
- Switch Disconnector Spare Parts
- Operator Touch Panels
- Overload Protection Device
- Terminal Block Accessories
- Power Capacitors
- Measuring Device
- Linear Measuring Encoders
- Distributed Drive System
- Programmable Logic Controllers
- Pyrometers
- Light Switches & Electrical Sockets
- Universal Protection Device
- Pressure Detectors
- All Products
- Schneider Electric
- LUCB32ES
Schneider Electric
LUCB32ES
The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information
Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.
Description for LUCB32ES Schneider Electric
LUCB32ES Schneider Electric - Advanced control unit, TeSys U, 8-32A, 3P motors, protection & diagnostic, class 10, coil 48-72V AC/DC
Extended Description for LUCB32ES Schneider Electric
LUCB32ES Schneider Electric - TeSys U control and diagnostic unit to be inserted in advanced power bases LUB320, LUB380, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 15kW@400V.,It provides full protection to motors with a rated current Ir 8-32A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only).,For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation.,To be used with a 48V AC / 48-72V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base).,Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Main
Range
TeSys
range of product
TeSys Ultra
Product name
TeSys Ultra
Device short name
LUCB
product or component type
Advanced control unit
device application
Motor control,Motor protection
Product specific application
Basic protection and advanced functions, communication
main function available
Protection against overload and short-circuit,Earth fault protection,Protection against phase failure and phase imbalance,Manual reset
Product compatibility
Power base LUB32,Power base LUB38,Power base LUB320,Power base LUB380,Reversing contactor breaker LU2B32ES
[Ue] rated operational voltage
690 V AC
Network frequency
40...60 Hz
Load type
3-phase motor - cooling: self-cooled
Utilisation category
AC-44,AC-43,AC-41
Motor power kW
15 kW at 400...440 V AC 50/60 Hz,15 kW at 500 V AC 50/60 Hz,18.5 kW at 690 V AC 50/60 Hz
rated motor current adjustment range
8…32 A
Thermal overload class
Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2,Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508
Tripping threshold
14.2 x Ir +/- 20 %
Phase failure sensitivity
Yes
[Uc] control circuit voltage
48 V AC,48...72 V DC
Complementary
Control circuit voltage limits
38.5...72 V for AC circuit 48 V in operation,38.5...93 V for DC circuit 48...72 V in operation,29 V for AC circuit 48 V drop-out,29 V for DC circuit 48...72 V drop-out
Typical current consumption
280 mA at 48 V AC I maximum while closing with LUB32,280 mA at 48 V AC I maximum while closing with LUB38,280 mA at 48...72 V DC I maximum while closing with LUB32,280 mA at 48...72 V DC I maximum while closing with LUB38,45 mA at 48 V AC I rms sealed with LUB32,45 mA at 48 V AC I rms sealed with LUB38,45 mA at 48...72 V DC I rms sealed with LUB32,45 mA at 48...72 V DC I rms sealed with LUB38
Heat dissipation
3 W for control circuit with LUB32,3 W for control circuit with LUB38
Operating time
35 ms opening with LUB32 for control circuit,35 ms opening with LUB38 for control circuit,60 ms closing with LUB32 for control circuit,60 ms closing with LUB38 for control circuit
Reset
Manual reset
Standards
EN 60947-6-2,IEC 60947-6-2,UL 60947-4-1, with phase barrier,CSA C22.2 No 60947-4-1, with phase barrier
Product certifications
CE,UL,CSA,CCC,EAC,ASEFA,ATEX,Marine
[Ui] rated insulation voltage
690 V conforming to IEC 60947-6-2,600 V conforming to UL 60947-4-1,600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-6-2
Safe separation of circuit
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1,400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Fixing mode
Plug-in (front face)
Width
45 mm
Height
66 mm
Depth
60 mm
compatibility code
LUCB
Environment
IP degree of protection
IP20 front panel and wired terminals conforming to IEC 60947-1,IP20 other faces conforming to IEC 60947-1,IP40 front panel outside connection zone conforming to IEC 60947-1
Protective treatment
TH conforming to IEC 60068
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…85 °C
Operating altitude
2000 m
Fire resistance
960 °C parts supporting live components conforming to IEC 60695-2-12,650 °C conforming to IEC 60695-2-12
Shock resistance
10 gn power poles open conforming to IEC 60068-2-27,15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance
2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6,4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
Resistance to electrostatic discharge
8 kV level 3 in open air conforming to IEC 61000-4-2,8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating shock wave
1 kV serial mode conforming to IEC 60947-6-2,2 kV common mode conforming to IEC 60947-6-2
Resistance to radiated fields
10 V/m 3 conforming to IEC 61000-4-3
Resistance to fast transients
2 kV class 3 serial link conforming to IEC 61000-4-4,4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Immunity to radioelectric fields
10 V conforming to IEC 61000-4-6
Immunity to microbreaks
3 ms
Immunity to voltage dips
70 % / 500 ms conforming to IEC 61000-4-11
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.5 cm
Package 1 Width
10.2 cm
Package 1 Length
8.6 cm
Package 1 Weight
125.0 g
Unit Type of Package 2
S02
Number of Units in Package 2
23
Package 2 Height
15.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
3.189 kg
Contractual warranty
Warranty
18 months
Documentation
Product Datasheet
Instruction sheet
Catalogue
CAD
Environmental disclosure
Looking for a specific part?
If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.