0AB
- B&R
- B&R Automation
- Baco
- Balluff
- Banner
- Banner Engineering
- Bartec
- Basler
- Baumer
- Baumer Electric
- Baumer Hubner
- Baumüller
- Beckhoff
- Beghelli
- Beijer Electronics
- Belden
- Belimo
- Bently Nevada
- Bernstein
- Betaduct
- Boardman Transformers
- Bopla
- Bosch Rexroth
- Bourns
- Broadcom
- BTI
- BTicino
- Burgess
- Burkert
- Busch Jaeger - ABB
- Bussmann
CDEHIKLMPS- Salzer
- Santon
- Sanyo Denki
- Scan
- Schaffner
- Schmersal
- Schneider
- Schneider Electric
- Schrack
- Seagate
- SEI DUE SEI
- Selet
- Semikron
- Seneca
- Sensopart
- SEW Eurodrive
- Sharp
- Siba
- Sick
- Siemens
- Siemens Burners
- Siemens Smart Infrastructure
- Sirena
- SKS Hirschmann Test & Measurement
- Smartscan
- SMC
- Socomec
- SolaHD
- Sontay
- Spectrum Controls
- Square D
- StarTech
- Staubli
- STEGO
- STMicroelectronics
- Sunon
- Supertouch
- Swissbit
- Synatel
TW -
- Circuit Breakers
- Relays
- Surge Protection
- Electric Motors
- Convertors
- Enclosures
- Sockets
- Low Voltage Components
- Robotics
- Motor Starter
- Other
- CPU Modules
- Push buttons
- Safety Switches
- Sensors
- Transformers
- Level Monitoring
- Distribution Block
- Terminal Blocks
- Motor Protection
- Industrial Safety Products
- Labelling
- Fuse Switch Disconnector
- Fuse
- Industrial Cables
- Isolator Switch
- Selector Switch
- Wire Terminals & Connectors
- Industrial Modules
- Industrial Enclosure,Door & Mounting Plates
- Industrial Spare Parts
- Cable Marker
- Busbar & Cable Ducts
- UPS Systems
- Contactors
- Siemens SIMATIC Range
- Electronic Module
- Power Unit
- Power Modules & Drives
- Operating Panels
- Industrial Switches
- Control Systems
- Industrial Handles
- Variable Frequency & Adjustable Speed Drives
- Drive Converters
- Servo Motor
- Industrial Gearbox Spares
- Planetary Gearbox
- Incremental Encoder
- Resistors
- Pressure Switches
- Ammeter
- Industrial Automation Software
- Crimp Terminals
- Industrial Sockets
- Power Supply
- Trunking
- DIN Rails
- Distance Measuring Device
- Industrial Beacons
- Potentiometer
- RCBO Circuit Breakers
- Distribution Board
- Actuators
- Circuit Protection
- Expansion Modules
- Ethernet Media
- Industrial Valves & Accessories
- Limit Switch
- Mounting Frames
- Servo Drives
- Control and Automation Board
- DIN Rail Mounting Device
- Meter Panel
- Industrial Key Switches
- Speed Controller
- Pilot Lights
- Stepper Motors
- Push-Pull Device
- Connection Products
- Low Voltage Product Spares
- Industrial Rating Plugs
- Interface Unit
- Stack Lighting
- Compact Cylinder
- Pressure Transmitter
- Ethernet Cables
- Line Differential & Distance Protection Device
- Tower Light
- Energy Meters
- Industrial Automation Mounting Kits
- Consumer Unit
- Junction Box
- Variable Frequency & Adjustable Speed Drivess
- Industrial Power Socket
- Encoders
- Load Switch
- Modular Tower Lights
- Contactor Relay & Protection Relays
- Power Contactor
- Distribution Panels
- Power Meter
- Pneumatic
- Brushless DC Motor
- Key-operated switch
- Pressure Regulator
- Cylinderical Gears
- Interior Fitting Systems
- Residual Current Device Block
- Proximity Sensor
- Terminal Markers
- Merging Unit
- Fault Recorder
- Overcurrent & Feed Protection Device
- Frequency Converters
- Load Monitoring Devices
- Thermal Overload
- Residual Current Monitors
- Control Stations
- Industrial Line Protection Device
- Solenoid Valve Connector
- Trapped Key Interlock
- Industrial Indicator Lights
- Motion controller
- Protective Relay
- Switch Disconnector Spare Parts
- Operator Touch Panels
- Overload Protection Device
- Terminal Block Accessories
- Power Capacitors
- Measuring Device
- Linear Measuring Encoders
- Distributed Drive System
- Programmable Logic Controllers
- Pyrometers
- Light Switches & Electrical Sockets
- Universal Protection Device
- Pressure Detectors
- All Products
- Schneider Electric
- LC2K0901U7
Schneider Electric
LC2K0901U7
The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information
Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.
Description for LC2K0901U7 Schneider Electric
LC2K0901U7 Schneider Electric - TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 230...240 VAC coil
Extended Description for LC2K0901U7 Schneider Electric
LC2K0901U7 Schneider Electric - TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V).,It provides 230-240V 50/60Hz AC coils, 2NC built-in auxiliary contacts, connection by screw clamp terminals.,For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications.,Compact (90mm width), DIN-rail mounting or screw fixing.,With pre-wired reversing power connections, mechanical interlock (without electrical interlocking).,Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Manufacturer New
33 available
1 - 2 w.days
£74.81
Exc. VAT
£89.77
Inc. VAT
Manufacturer New
Available for Back Order
£115.69
Exc. VAT
£138.83
Inc. VAT
Direct from Manufacturer
Available on back order
4 - 6 W.Weeks
£38.19
Exc. VAT
£45.83
Inc. VAT
Main
Range
TeSys
Product name
TeSys K
product or component type
Reversing contactor
Device short name
LC2K
device application
Control
Contactor application
Resistive load,Motor control
Utilisation category
AC-3,AC-3e,AC-4,AC-1
Device presentation
Preassembled with reversing power busbar
Poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit: 690 V AC 50/60 Hz,Signalling circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current
9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit,9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit,20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Motor power kW
2.2 kW at 220...230 V AC 50/60 Hz,4 kW at 380...415 V AC 50/60 Hz,4 kW at 440/690 V AC 50/60 Hz
Control circuit type
AC at 50/60 Hz
[Uc] control circuit voltage
230...240 V AC 50/60 Hz
Auxiliary contact composition
1 NC
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
[Ith] conventional free air thermal current
20 A (at 60 °C) for power circuit,10 A (at 50 °C) for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to IEC 60947,110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity
110 A at 220...230 V conforming to IEC 60947,110 A at 380...400 V conforming to IEC 60947,110 A at 415 V conforming to IEC 60947,110 A at 440 V conforming to IEC 60947,80 A at 500 V conforming to IEC 60947,70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current
90 A 50 °C - 1 s for power circuit,85 A 50 °C - 5 s for power circuit,80 A 50 °C - 10 s for power circuit,60 A 50 °C - 30 s for power circuit,45 A 50 °C - 1 min for power circuit,40 A 50 °C - 3 min for power circuit,20 A 50 °C - >= 15 min for power circuit,80 A - 1 s for signalling circuit,90 A - 500 ms for signalling circuit,110 A - 100 ms for signalling circuit
Associated fuse rating
25 A gG at <= 440 V for power circuit,25 A aM for power circuit,10 A gG for signalling circuit conforming to IEC 60947,10 A gG for signalling circuit conforming to VDE 0660
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage
Power circuit: 600 V conforming to UL 508,Power circuit: 690 V conforming to IEC 60947-4-1,Signalling circuit: 690 V conforming to IEC 60947-4-1,Signalling circuit: 690 V conforming to IEC 60947-5-1,Signalling circuit: 600 V conforming to UL 508,Power circuit: 600 V conforming to CSA C22.2 No 14,Signalling circuit: 600 V conforming to CSA C22.2 No 14
Electrical durability
1.3 Mcycles 9 A AC-3 at Ue <= 440 V,1.3 Mcycles 9 A AC-3e at Ue <= 440 V,0.16 Mcycles 20 A AC-1 at Ue <= 690 V,0.02 Mcycles 54 A AC-4 at Ue <= 440 V
Interlocking type
Mechanical
mounting support
Rail,Plate
Standards
EN/IEC 60947-4-1,GB/T 14048.4,UL 60947-4-1,CSA C22.2 No 60947-4-1,JIS C8201-4-1
Product certifications
CB Scheme,CCC,UL,CSA,EAC,CE,UKCA
Connections - terminals
Screw clamp terminals 1 cable(s) 1.5…4 mm²solid,Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end,Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end,Screw clamp terminals 2 cable(s) 1.5…4 mm²solid,Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end,Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque
0.8…1.3 N.m - on screw clamp terminals Philips No 2,0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm,0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Operating time
10...20 ms coil energisation and NO closing,10...20 ms coil de-energisation and NO opening
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability
5 Mcycles
Maximum operating rate
3600 cyc/h
Complementary
Control circuit voltage limits
Operational: 0.8...1.15 Uc (at <50 °C),Drop-out: 0.2...0.75 Uc (at <50 °C)
Inrush power in VA
30 VA (at 20 °C)
Hold-in power consumption in VA
4.5 VA (at 20 °C)
Heat dissipation
1.3 W
Auxiliary contacts type
type instantaneous 1 NC
Signalling circuit frequency
<= 400 Hz
Minimum switching current
5 mA for signalling circuit
Minimum switching voltage
17 V for signalling circuit
Non overlap distance
0.5 mm
Insulation resistance
> 10 MOhm for signalling circuit
Environment
IP degree of protection
IP20 conforming to VDE 0106
Protective treatment
TC conforming to IEC 60068,TC conforming to DIN 50016
Ambient air temperature for operation
-25…50 °C
Ambient air temperature for storage
-50…80 °C
Operating altitude
2000 m without derating
Flame retardance
V1 conforming to UL 94,Requirement 2 conforming to NF F 16-101,Requirement 2 conforming to NF F 16-102
Mechanical robustness
Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6,Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Height
58 mm
Width
90 mm
Depth
57 mm
net weight
0.39 kg
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
6.5 cm
Package 1 Width
9.2 cm
Package 1 Length
6.0 cm
Package 1 Weight
367.0 g
Unit Type of Package 2
S02
Number of Units in Package 2
25
Package 2 Height
15.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
9.501 kg
Contractual warranty
Warranty
18 months
Documentation
Product Datasheet
Instruction sheet
Catalogue
CAD
Environmental disclosure
Looking for a specific part?
If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.