Schneider Electric

LC2D18F7V

LC2D18F7V Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LC2D18F7V Schneider Electric

LC2D18F7V Schneider Electric - TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 110 V AC coil

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£61.69 Exc. VAT
£74.03 Inc. VAT

Main

Range TeSys
Product name TeSys Deca
product or component type Reversing contactor
Device short name LC2D
Contactor application Resistive load,Motor control
Utilisation category AC-1,AC-3
Device presentation Preassembled with reversing power busbar
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz,Power circuit: <= 300 V DC
[Ie] rated operational current 18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit,32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Motor power kW 4 kW at 220...230 V AC 50 Hz,7.5 kW at 380...400 V AC 50 Hz,9 kW at 415...440 V AC 50 Hz,10 kW at 500 V AC 50 Hz,10 kW at 660...690 V AC 50 Hz
motor power HP (UL / CSA) 1 hp at 115 V AC 60 Hz for 1 phase motors,3 hp at 230/240 V AC 60 Hz for 1 phase motors,5 hp at 200/208 V AC 60 Hz for 3 phases motors,5 hp at 230/240 V AC 60 Hz for 3 phases motors,10 hp at 460/480 V AC 60 Hz for 3 phases motors,15 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 110 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit,32 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1,250 A DC for signalling circuit conforming to IEC 60947-5-1,300 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 40 A 40 °C - 10 min for power circuit,84 A 40 °C - 1 min for power circuit,145 A 40 °C - 10 s for power circuit,240 A 40 °C - 1 s for power circuit,100 A - 1 s for signalling circuit,120 A - 500 ms for signalling circuit,140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1,50 A gG at <= 690 V coordination type 1 for power circuit,35 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm - Ith 32 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1,Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Signalling circuit: 690 V conforming to IEC 60947-1,Signalling circuit: 600 V CSA certified,Signalling circuit: 600 V UL certified
Electrical durability 1.65 Mcycles 18 A AC-3 at Ue <= 440 V,1 Mcycles 32 A AC-1 at Ue <= 440 V
Power dissipation per pole 0.8 W AC-3,2.5 W AC-1
Front cover With
Interlocking type Electrical and mechanical
mounting support Plate,Rail
Standards CSA C22.2 No 14,EN 60947-4-1,EN 60947-5-1,IEC 60947-4-1,IEC 60947-5-1,UL 508
Product certifications CCC,UL,BV,GL,CSA,LROS (Lloyds register of shipping),DNV,RINA,GOST
Connections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end,Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end,Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid,Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid,Power circuit: screw clamp terminals 1 cable(s) 1.5…6 mm²flexible without cable end,Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible without cable end,Power circuit: screw clamp terminals 1 cable(s) 1…6 mm²flexible with cable end,Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end,Power circuit: screw clamp terminals 1 cable(s) 1.5…6 mm²solid,Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²solid
Tightening torque Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm,Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2,Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm,Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Operating time 12...22 ms closing,4...19 ms opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 15 Mcycles
Maximum operating rate 3600 cyc/h 60 °C

Complementary

Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz,0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz,0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz,1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C),70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C),7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W at 50/60 Hz
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact,1.5 ms on energisation between NC and NO contact
Insulation resistance > 10 MOhm for signalling circuit

Environment

IP degree of protection IP20 front face conforming to IEC 60529
Climatic withstand conforming to IACS E10, conforming to IEC 60947-1 Annex Q category D
Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -40…60 °C,60…70 °C with derating
Ambient air temperature for storage -60…80 °C
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz,Vibrations contactor closed: 4 Gn, 5...300 Hz,Shocks contactor open: 10 Gn for 11 ms,Shocks contactor closed: 15 Gn for 11 ms
Height 77 mm
Width 90 mm
Depth 86 mm
net weight 0.707 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.4 cm
Package 1 Width 11.4 cm
Package 1 Length 11 cm
Package 1 Weight 730 g

Contractual warranty