0AB
- B&R
- B&R Automation
- Baco
- Balluff
- Banner
- Banner Engineering
- Bartec
- Basler
- Baumer
- Baumer Electric
- Baumer Hubner
- Baumüller
- Beckhoff
- Beghelli
- Beijer Electronics
- Belden
- Belimo
- Bently Nevada
- Bernstein
- Betaduct
- Boardman Transformers
- Bopla
- Bosch Rexroth
- Bourns
- Broadcom
- BTI
- BTicino
- Burgess
- Burkert
- Busch Jaeger - ABB
- Bussmann
CDEHIKLMPS- Salzer
- Santon
- Sanyo Denki
- Scan
- Schaffner
- Schmersal
- Schneider
- Schneider Electric
- Schrack
- Seagate
- SEI DUE SEI
- Selet
- Semikron
- Seneca
- Sensopart
- SEW Eurodrive
- Sharp
- Siba
- Sick
- Siemens
- Siemens Burners
- Siemens Smart Infrastructure
- Sirena
- SKS Hirschmann Test & Measurement
- Smartscan
- SMC
- Socomec
- SolaHD
- Sontay
- Spectrum Controls
- Square D
- StarTech
- Staubli
- STEGO
- STMicroelectronics
- Sunon
- Supertouch
- Swissbit
TW -
- Circuit Breakers
- Relays
- Surge Protection
- Electric Motors
- Convertors
- Enclosures
- Sockets
- Low Voltage Components
- Robotics
- Motor Starter
- Other
- CPU Modules
- Push buttons
- Safety Switches
- Sensors
- Transformers
- Level Monitoring
- Distribution Block
- Terminal Blocks
- Motor Protection
- Industrial Safety Products
- Labelling
- Fuse Switch Disconnector
- Fuse
- Industrial Cables
- Isolator Switch
- Selector Switch
- Wire Terminals & Connectors
- Industrial Modules
- Industrial Enclosure,Door & Mounting Plates
- Industrial Spare Parts
- Cable Marker
- Busbar & Cable Ducts
- UPS Systems
- Contactors
- Siemens SIMATIC Range
- Electronic Module
- Power Unit
- Power Modules & Drives
- Operating Panels
- Industrial Switches
- Control Systems
- Industrial Handles
- Variable Frequency & Adjustable Speed Drives
- Drive Converters
- Servo Motor
- Industrial Gearbox Spares
- Planetary Gearbox
- Incremental Encoder
- Resistors
- Pressure Switches
- Ammeter
- Industrial Automation Software
- Crimp Terminals
- Industrial Sockets
- Power Supply
- Trunking
- DIN Rails
- Distance Measuring Device
- Industrial Beacons
- Potentiometer
- RCBO Circuit Breakers
- Distribution Board
- Actuators
- Circuit Protection
- Expansion Modules
- Ethernet Media
- Industrial Valves & Accessories
- Limit Switch
- Mounting Frames
- Servo Drives
- Control and Automation Board
- DIN Rail Mounting Device
- Meter Panel
- Industrial Key Switches
- Speed Controller
- Pilot Lights
- Stepper Motors
- Push-Pull Device
- Connection Products
- Low Voltage Product Spares
- Industrial Rating Plugs
- Interface Unit
- Stack Lighting
- Compact Cylinder
- Pressure Transmitter
- Ethernet Cables
- Line Differential & Distance Protection Device
- Tower Light
- Energy Meters
- Industrial Automation Mounting Kits
- Consumer Unit
- Junction Box
- Variable Frequency & Adjustable Speed Drivess
- Industrial Power Socket
- Encoders
- Load Switch
- Modular Tower Lights
- Contactor Relay & Protection Relays
- Power Contactor
- Distribution Panels
- Power Meter
- Pneumatic
- Brushless DC Motor
- Key-operated switch
- Pressure Regulator
- Cylinderical Gears
- Interior Fitting Systems
- Residual Current Device Block
- Proximity Sensor
- Terminal Markers
- Merging Unit
- Fault Recorder
- Overcurrent & Feed Protection Device
- Frequency Converters
- Load Monitoring Devices
- Thermal Overload
- Residual Current Monitors
- Control Stations
- Industrial Line Protection Device
- Solenoid Valve Connector
- Trapped Key Interlock
- Industrial Indicator Lights
- Motion controller
- Protective Relay
- Switch Disconnector Spare Parts
- Operator Touch Panels
- Overload Protection Device
- Terminal Block Accessories
- Power Capacitors
- Measuring Device
- Linear Measuring Encoders
- Distributed Drive System
- Programmable Logic Controllers
- Pyrometers
- Light Switches & Electrical Sockets
- Universal Protection Device
- Pressure Detectors
- All Products
- Schneider Electric
- LC1D25Y7
Schneider Electric
LC1D25Y7
The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information
Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.
Description for LC1D25Y7 Schneider Electric
LC1D25Y7 Schneider Electric - TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 690 V AC coil
Direct from Manufacturer
Available on back order
4 - 6 W.Weeks
£42.69
Exc. VAT
£51.22
Inc. VAT
Main
range of product
TeSys Deca
product or component type
Contactor
Device short name
LC1D
Contactor application
Resistive load,Motor control
Utilisation category
AC-1,AC-4,AC-3,AC-3e
Poles description
3P
[Ue] rated operational voltage
Power circuit: <= 690 V AC 25...400 Hz,Power circuit: <= 300 V DC
[Ie] rated operational current
25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit,40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit,25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage
690 V AC 50/60 Hz
Complementary
Motor power kW
5.5 kW at 220...230 V AC 50/60 Hz (AC-3),11 kW at 380...400 V AC 50/60 Hz (AC-3),11 kW at 415...440 V AC 50/60 Hz (AC-3),15 kW at 500 V AC 50/60 Hz (AC-3),15 kW at 660...690 V AC 50/60 Hz (AC-3),5.5 kW at 400 V AC 50/60 Hz (AC-4),5.5 kW at 220...230 V AC 50/60 Hz (AC-3e),11 kW at 380...400 V AC 50/60 Hz (AC-3e),11 kW at 415...440 V AC 50/60 Hz (AC-3e),15 kW at 500 V AC 50/60 Hz (AC-3e),15 kW at 660...690 V AC 50/60 Hz (AC-3e)
Motor power hp
3 hp at 230/240 V AC 50/60 Hz for 1 phase motors,2 hp at 115 V AC 50/60 Hz for 1 phase motors,7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors,15 hp at 460/480 V AC 50/60 Hz for 3 phases motors,20 hp at 575/600 V AC 50/60 Hz for 3 phases motors,7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
compatibility code
LC1D
Pole contact composition
3 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 60 °C) for signalling circuit,40 A (at 60 °C) for power circuit
Irms rated making capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1,250 A DC for signalling circuit conforming to IEC 60947-5-1,450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
240 A 40 °C - 10 s for power circuit,380 A 40 °C - 1 s for power circuit,50 A 40 °C - 10 min for power circuit,120 A 40 °C - 1 min for power circuit,100 A - 1 s for signalling circuit,120 A - 500 ms for signalling circuit,140 A - 100 ms for signalling circuit
Associated fuse rating
10 A gG for signalling circuit conforming to IEC 60947-5-1,63 A gG at <= 690 V coordination type 1 for power circuit,40 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
2 mOhm - Ith 40 A 50 Hz for power circuit
Power dissipation per pole
3.2 W AC-1,1.25 W AC-3,2 W AC-3e
[Ui] rated insulation voltage
Power circuit: 690 V conforming to IEC 60947-4-1,Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Signalling circuit: 690 V conforming to IEC 60947-1,Signalling circuit: 600 V CSA certified,Signalling circuit: 600 V UL certified
Overvoltage category
III
Pollution degree
3
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability
15 Mcycles
Electrical durability
1.65 Mcycles 25 A AC-3 at Ue <= 440 V,1.4 Mcycles 40 A AC-1 at Ue <= 440 V,1.65 Mcycles 25 A AC-3e at Ue <= 440 V
Control circuit type
AC at 50/60 Hz
Coil technology
Without built-in suppressor module
Control circuit voltage limits
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz,0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz,0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz,1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA
70 VA 60 Hz cos phi 0.75 (at 20 °C),70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA
7.5 VA 60 Hz cos phi 0.3 (at 20 °C),7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation
2…3 W at 50/60 Hz
Operating time
12...22 ms closing,4...19 ms opening
Maximum operating rate
3600 cyc/h 60 °C
Maximum operating rate
3600 cyc/h at 60 °C
Connections - terminals
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end,Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end,Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end,Power circuit: screw clamp terminals 1 1…10 mm² - cable stiffness: flexible with cable end,Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: flexible with cable end,Power circuit: screw clamp terminals 1 1.5…10 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: solid without cable end
Tightening torque
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm,Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2,Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm,Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
Auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency
25...400 Hz
Minimum switching voltage
17 V for signalling circuit
Minimum switching current
5 mA for signalling circuit
Insulation resistance
> 10 MOhm for signalling circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contact,1.5 ms on energisation between NC and NO contact
mounting support
Plate,Rail
Environment
Standards
CSA C22.2 No 14,EN 60947-4-1,EN 60947-5-1,IEC 60947-4-1,IEC 60947-5-1,UL 60947-4-1,IEC 60335-1:Clause 30.2,IEC 60335-2-40:Annex JJ,UL 60335-2-40:Annex JJ,CSA C22.2 No 60947-4-1
Product certifications
UL,CCC,CSA,Marine,UKCA,EAC,CB Scheme
IP degree of protection
IP20 front face conforming to IEC 60529
Protective treatment
TH conforming to IEC 60068-2-30
Climatic withstand
conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device
-40…60 °C,60…70 °C with derating
Operating altitude
0...3000 m
Fire resistance
850 °C conforming to IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor open (2 Gn, 5...300 Hz) ,Vibrations contactor closed (4 Gn, 5...300 Hz) ,Shocks contactor closed (15 Gn for 11 ms) ,Shocks contactor open (8 Gn for 11 ms)
Height
85 mm
Width
45 mm
Depth
92 mm
net weight
0.37 kg
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
10.9 cm
Package 1 Width
9.0 cm
Package 1 Length
5.4 cm
Package 1 Weight
370.0 g
Contractual warranty
Warranty
18 months
Documentation
Product Datasheet
Instruction sheet
Catalogue
CAD
Environmental disclosure
Looking for a specific part?