Schneider Electric

ATV340U07N4

ATV340U07N4 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for ATV340U07N4 Schneider Electric

ATV340U07N4 Schneider Electric - variable speed drive - 0.75kW - 400V - 3 phases - ATV340

Extended Description for ATV340U07N4 Schneider Electric

ATV340U07N4 Schneider Electric - This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control.,Altivar Machine ATV340 drives are sized heavy duty as standard.,It works at a rated power up to 0.75kW / 1hp and a rated voltage from 380V to 480V AC.,ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed.,This product integrates Modbus serial line communication protocols as standard.,it weighs 1.7kg and its dimensions are, 85mm wide, 270mm high, 232.5mm deep.,ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting.,It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÃV certified.,Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating.,It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes.,It is fully integrated inside Schneider Electricâs EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).

Free Delivery to UK Mainland on orders over £25

Manufacturer New

3 available
1 - 2 w.days
£554.83 Exc. VAT
£665.80 Inc. VAT

Manufacturer New

9 available
5 - 8 w.days
£387.07 Exc. VAT
£464.48 Inc. VAT

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£299.72 Exc. VAT
£359.66 Inc. VAT

Main

range of product Altivar Machine ATV340
product or component type Variable speed drive
Product specific application Machine
mounting mode Cabinet mount
Variant Standard version
communication port protocol Modbus serial
Option card Communication module, Profibus DP V1,Communication module, PROFINET,Communication module, DeviceNet,Communication module, CANopen,Communication module, EtherCAT
Network number of phases 3 phases
Supply frequency 50...60 Hz +/- 5 %
[Us] rated supply voltage 380...480 V - 15...10 %
Nominal output current 2.2 A
Motor power kW 1.1 kW for normal duty,0.75 kW for heavy duty
Motor power hp 1.5 hp for normal duty,1 hp for heavy duty
EMC filter Class C3 EMC filter integrated
IP degree of protection IP20

Complementary

Discrete input number 5
Discrete input type PTI programmable as pulse input: 0…30 kHz, 24 V DC (30 V),DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm, programmable
number of preset speeds 16 preset speeds
Discrete output number 2.0
Discrete output type Programmable output DQ1, DQ2 30 V DC 100 mA
Analogue input number 2
Analogue input type AI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits,AI1 software-configurable temperature probe or water level sensor,AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits,AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue output number 1
Analogue output type Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits,Software-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits
Relay output number 2
Output voltage <= power supply voltage
Relay output type Relay outputs R1A,Relay outputs R1C electrical durability 100000 cycles,Relay outputs R2A,Relay outputs R2C electrical durability 100000 cycles
Maximum switching current Relay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC,Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC,Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC,Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC,Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC,Relay output R2C on resistive load, cos phi = 1: 5 A at 30 V DC,Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC,Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching current Relay output R1B: 5 mA at 24 V DC,Relay output R2C: 5 mA at 24 V DC
Physical interface 2-wire RS 485
Connector type 1 RJ45
Method of access Slave Modbus RTU
Transmission rate 4.8 kbit/s,9.6 kbit/s,19.2 kbit/s,38.4 kbit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Constant torque standard,Variable torque standard,Optimized torque mode
Synchronous motor control profile Permanent magnet motor,Reluctance motor
Pollution degree 2 conforming to IEC 61800-5-1
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps S, U or customized,Linear adjustable separately from 0.01...9999 s
Motor slip compensation Can be suppressed,Not available in permanent magnet motor law,Automatic whatever the load,Adjustable
Switching frequency 2...16 kHz adjustable,14...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 2.6 A at 380 V (normal duty),2.1 A at 480 V (normal duty),3.4 A at 380 V (heavy duty),2.6 A at 480 V (heavy duty)
Line current 2.6 A at 480 V without line choke (heavy duty),2.6 A at 380 V with external line choke (normal duty),2.1 A at 480 V with external line choke (normal duty),1.9 A at 380 V with external line choke (heavy duty),1.6 A at 480 V with external line choke (heavy duty),3.4 A at 380 V without line choke (heavy duty)
Maximum input current 3.4 A
Maximum output voltage 480 V
Apparent power 2.2 kVA at 480 V (normal duty),2.2 kVA at 480 V (heavy duty)
Maximum transient current 3.1 A during 60 s (normal duty),3.3 A during 60 s (heavy duty),3.8 A during 2 s (normal duty),4 A during 2 s (heavy duty)
Electrical connection Screw terminal, clamping capacity: 1.5...4 mm² for line side,Screw terminal, clamping capacity: 4...6 mm² for DC bus,Screw terminal, clamping capacity: 1.5...4 mm² for motor,Screw terminal, clamping capacity: 0.2...2.5 mm² for control
Prospective line Isc 5 kA
Base load current at high overload 2.2 A
Base load current at low overload 2.8 A
Power dissipation in W Natural convection: 28 W at 380 V, switching frequency 4 kHz (heavy duty),Forced convection: 28 W at 380 V, switching frequency 4 kHz (heavy duty),Natural convection: 33 W at 380 V, switching frequency 4 kHz (normal duty),Forced convection: 33 W at 380 V, switching frequency 4 kHz (normal duty)
Electrical connection Line side: screw terminal 1.5...4 mm²/AWG 14...AWG 12,DC bus: screw terminal 4...6 mm²/AWG 12...AWG 10,Motor: screw terminal 1.5...4 mm²/AWG 14...AWG 12,Control: screw terminal 0.2...2.5 mm²/AWG 24...AWG 12
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection: motor,Safe torque off: motor,Motor phase loss: motor,Thermal protection: drive,Safe torque off: drive,Overheating: drive,Overcurrent: drive,Output overcurrent between motor phase and earth: drive,Output overcurrent between motor phases: drive,Short-circuit between motor phase and earth: drive,Short-circuit between motor phases: drive,Motor phase loss: drive,DC Bus overvoltage: drive,Line supply overvoltage: drive,Line supply undervoltage: drive,Input supply loss: drive,Exceeding limit speed: drive,Break on the control circuit: drive
Width 85.0 mm
Height 270.0 mm
Depth 232.5 mm
net weight 1.7 kg
Continuous output current 2.2 A at 4 kHz for heavy duty,2.8 A at 4 kHz for normal duty

Environment

Operating altitude <= 3000 m with current derating above 1000m
Operating position Vertical +/- 10 degree
Product certifications UL,CSA,TÜV,EAC,CTick
marking CE
Standards IEC 61800-3,IEC 61800-5-1,IEC 60721-3,IEC 61508,IEC 13849-1,UL 618000-5-1,UL 508C
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2,Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3,Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4,1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5,Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3,Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 70 m/s² at 22 ms
Maximum acceleration under vibrational stress (during operation) 5 m/s² at 9...200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2...9 Hz
Permitted relative humidity (during operation) Class 3K5 according to EN 60721-3
Volume of cooling air 18.0 m3/h
Type of cooling Forced convection
Overvoltage category Class III
Regulation loop Adjustable PID regulator
Noise level 52.7 dB
Pollution degree 2
Ambient air transport temperature -40…70 °C
Ambient air temperature for operation -15…50 °C without derating (vertical position),50…60 °C with derating factor (vertical position)
Ambient air temperature for storage -40…70 °C
Isolation Between power and control terminals

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 10.700 cm
Package 1 Width 35.300 cm
Package 1 Length 28.800 cm
Package 1 Weight 2.432 kg
Unit Type of Package 2 P06
Number of Units in Package 2 14
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 47.048 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible