Description for ABLM1A12042 Schneider Electric

ABLM1A12042 Schneider Electric - Regulated Power Supply, 100-240V AC, 12V 4.2 A, single phase, Modular

Extended Description for ABLM1A12042 Schneider Electric

ABLM1A12042 Schneider Electric - This ABLM regulated switch mode power supply (SMPS) supplies direct current voltage.,It has a rated input of 100V to 240V AC, a rated output current of 4,17A at 12V DC and a rated power output of 50W.,It is ideal for supplying DC voltage necessary for automation equipment designed for applications in industrial, commercial and residential applications such as conveying, packaging, control, food & beverage, mining, oil & gas and water.,It installs on omega rail or fixing by screw. Its width is 53mm, its height is 91mm, its depth is 55,6mm.,It ensures a protection against overloads and short-circuits with automatic restart after the source of overload/short-circuit has been corrected.,It weighs 0.221kg,It is a power supply for industrial use, rail mounting.,It conforms to EN62368-1, ENIEC61010-1/2-201, ENIEC61204-3, EN61000-6-1/2/3/4, EN61000-3-2-3, UL62368-1, UL61010-2-201/-1-201, CSAC22.2No62368-1/No61010-2-201/No61010-1 standards, and certified by CE, CUL listed/recognized, RCM, CBscheme.,The Acti9 iC60 range of Miniature Circuit Breakers is recommanded for its protection. The type of protection is 6A, C curve or 10A, B-curve.,It has in the front face a LED indicating presence of DC output voltage, and a QR code for access to the latest technical documentation.,Thanks to their modular housing, they can be installed either in enclosures or industrial panels by clipping on omega (DIN) rail.,It brings energy to your automated systems. Designed for simple machines and applications, modular power supplies are primarily appreciated for their extreme compactness.

Free Delivery to UK Mainland on orders over £25

Manufacturer New

1 available
1 - 2 w.days
£198.03 Exc. VAT
£237.64 Inc. VAT

Manufacturer New

4 available
5 - 8 w.days
£107.17 Exc. VAT
£128.61 Inc. VAT

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£63.57 Exc. VAT
£76.29 Inc. VAT

Main

range of product Modicon Power Supply
product or component type Power supply
power supply type Regulated switch mode
Variant option Modular
Enclosure material Plastic
Nominal input voltage 100...240 V AC single phase,100...240 V AC phase to phase
Rated power in W 50 W
Output voltage 12 V DC
Power supply output current 4.17 A

Complementary

Input voltage limits 90...264 V AC
Nominal network frequency 50…60 Hz
Network system compatibility TN,TT,IT
Maximum leakage current 0.25 mA 240 V AC
Input protection type Integrated fuse (not interchangeable) 3.15 A,External protection (recommended) 20 A Curve B,External protection (recommended) 20 A Curve C,External protection (recommended) 10 A Curve B,External protection (recommended) 6 A Curve C
Inrush current 30 A at 115 V,60 A at 230 V
Power factor 0.50 at 115 V AC,0.39 at 230 V AC
Efficiency 88 % at 115 V AC,88 % at 230 V AC
Output voltage adjustment 12...15 V
Power dissipation in W 5.5 W
Current consumption < 1.5 A 115 V AC,< 1 A 230 V AC
Turn-on time < 2 s
Holding time > 20 ms 115 V AC,> 60 ms 230 V AC
Startup with capacitive loads 3000 µF
Residual ripple < 100 mV
Meantime between failure [MTBF] 1500000 h at 25 °C, full load,1000000 h at 55 °C, 80 % load
Output protection type Against overload and short-circuits, protection technology: automatic reset,Against over temperature, protection technology: manual reset,Against overvoltage, protection technology: manual reset
Connections - terminals Screw connection: 0.5...2.5 mm², (AWG 20...AWG 14) without wire end ferrule for output,Screw connection: 0.5...1.5 mm², (AWG 20...AWG 16) with wire end ferrule for output,Screw connection: 0.5...1.5 mm², (AWG 20...AWG 16) for input
Line and load regulation < 0.5 % at in line,< 1 % at 0 to 100 % load
Status LED 1 LED (green) output voltage
Depth 55.6 mm
Height 91 mm
Width 53 mm
net weight 0.221 kg
Output coupling Serial,Parallel
Mounting support Top hat type TH35-15 rail conforming to IEC 60715,Top hat type TH35-7.5 rail conforming to IEC 60715,Double-profile DIN rail, panel mounting
Supply SELV conforming to IEC 60950-1,SELV conforming to IEC 60204-1,SELV conforming to IEC 60364-4-41
Dielectric strength 3000 V AC input/output
Service life 10 year(s)
Overvoltage category II

Environment

Standards IEC 62368-1,EN/IEC 61010-1,EN 61010-2-201,EN/IEC 61204-3,IEC 61000-6-1,IEC 61000-6-2,IEC 61000-6-3,IEC 61000-6-4,IEC 61000-3-2,EN 61000-3-3,UL 62368-1,UL 61010-1,UL 61010-2-201,CSA C22.2 No 62368-1,CSA C22.2 No 61010-1,CSA C22.2 No 61010-2-201,EN/IEC 62368-1
Product certifications CE,CUL listed,CUL recognized,RCM,CB Scheme,EAC,KC,NEC: class 2
Operating altitude < 2000 m overvoltage category III,2000 m...5000 m overvoltage category II
Shock resistance 150 m/s² for 11 ms
IP degree of protection IP20
Ambient air temperature for operation -25…55 °C without current derating mounting position A < 2000 m,55…70 °C with current derating of 2.67 % per °C mounting position A < 2000 m
Electrical shock protection class Class II without PE connection
Pollution degree 2
Vibration resistance 3 mm (f= 2…9 Hz) conforming to IEC 60721-3-3,10 m/s² (f= 9…200 Hz) conforming to IEC 60721-3-3
Electromagnetic immunity Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2,Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2,Electromagnetic field immunity test - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3,Electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3,Electromagnetic field immunity test - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3,Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4,Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5,Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5,Immunity to conducted disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6,Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8,Immunity to voltage dips - test level: 100 % (1 cycle) conforming to IEC 61000-4-11,Immunity to voltage dips - test level: 60 % (10 cycles) conforming to IEC 61000-4-11,Immunity to voltage dips - test level: 30 % (25 cycles) conforming to IEC 61000-4-11,Disturbing field emission conforming to EN 55016-2-3,Limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1
Electromagnetic emission Conducted emissions conforming to IEC 61000-6-3,Radiated emissions conforming to IEC 61000-6-4

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.100 cm
Package 1 Width 6.100 cm
Package 1 Length 11.000 cm
Package 1 Weight 228.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 24
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 5.819 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible