Siemens

3SE5112-0LA00-1CA0

Siemens 3SE5112-0LA00-1CA0

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for Siemens 3SE5112-0LA00-1CA0

Siemens 3SE5112-0LA00-1CA0 - Basic switch with increased corrosion protection for position switch Metal enclosure, according to EN 50041 Device connection 1 x (M20 x 1.5) 1 NO/2 NC quick action contacts without actuator head

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 3 W.Weeks

£20.60 Exc. VAT
£24.72 Inc. VAT

Manufacturer New

1 available
5 - 8 w.days
£67.33 Exc. VAT
£80.80 Inc. VAT

General Technical Data

Product Function Positive Opening Yes
Insulation Voltage Rated Value 400 V
Degree Of Pollution Class 3
Surge Voltage Resistance Rated Value 6 Kv
Shock Resistance
According To Iec 60068-2-27 30G / 11 Ms
Vibration Resistance According To Iec 60068-2-6 0.35 Mm/5G
Mechanical Service Life (Operating Cycles) Typical 15 000 000
Electrical Endurance (Operating Cycles) At Ac-15 At 230 V
Typical100 000
Thermal Current 10 A
Reference Code According To Iec 81346-2 B
Continuous Current Of The C Characteristic Mcb 1 A; For A Short-Circuit Current Smaller Than 400 A
Continuous Current Of The Quick Diazed Fuse Link 10 A; For A Short-Circuit Current Smaller Than 400 A
Continuous Current Of The Diazed Fuse Link Gg 6 A
Active Principle Mechanical
Repeat Accuracy 0.05 Mm
Substance Prohibitance (Date) 07/01/2006
Svhc Substance Name Imidazolidine-2-Thione (2-Imidazoline-2-Thiol) - 96-45-7
Weight 0.316 Kg
Minimum Actuating Force In Directions Of Actuation 20 N
Length Of The Sensor 85.7 Mm
Width Of The Sensor 40 Mm

Ambient Conditions

Ambient Temperature
During Operation -25 ... +85 °C
During Storage -40 ... +90 °C
Explosion Protection Category For Dust None

Main Circuit

Design Of The Switching Contact Mechanical
Operating Frequency Rated Value 50 ... 60 Hz
Number Of Nc Contacts For Auxiliary Contacts 2
Number Of No Contacts For Auxiliary Contacts 1
Operation Al Current At Ac-15
At 24 V Rated Value 6 A
At 125 V Rated Value 6 A
At 240 V Rated Value 6 A
At 400 V Rated Value 4 A
Operation Al Current At Dc-13
At 24 V Rated Value 3 A
At 125 V Rated Value 0.55 A
At 250 V Rated Value 0.27 A
At 400 V Rated Value 0.12 A
Enclosure
Design Of The Housing Block, Narrow
Material Of The Enclosure Metal
Coating Of The Enclosure Cathodic Dip Coating
Design Of The Housing According To Standard Yes
Drive Head
Design Of The Actuating Element Other, Without, Basic Switch
Design Of The Switching Function Positive Opening With Appropriate Positive Opening Actuator Head
Circuit Principle Snap-Action Contacts
Number Of Switching Contacts Safety-Related 2
Cable Entry Type 1X (M20 X 1.5)
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Screw Fixing

Connections/ Terminals

Type Of Electrical Connection Screw Terminal
Type Of Connectable Conductor Cross-Sections
Solid 1X (0.5 ... 1.5 Mm²), 2X (0.5 ... 0.75 Mm²)
Finely Stranded With Core End Processing 1X (0.5 ... 1.5 Mm²), 2X (0.5 ... 0.75 Mm²)
For Awg Cables Solid 1X (20 ... 16), 2X (20 ... 18)
For Awg Cables Stranded 1X (20 ... 16), 2X (20 ... 18)
Design Of The Interface For Safety-Related Communication Without

Communication/ Protocol

Design Of The Interface Without

Documentation