Siemens

6ES7136-6DC00-0CA0

Siemens 6ES7136-6DC00-0CA0

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for Siemens 6ES7136-6DC00-0CA0

Siemens 6ES7136-6DC00-0CA0 - ET 200SP. F-DQ 8X 24VDC/0.5A PP

Extended Description for Siemens 6ES7136-6DC00-0CA0

Siemens 6ES7136-6DC00-0CA0 - SIMATIC DP, electronic module ET 200SP, F-DQ 8x24VDC/0.5A PP HF, 15 mm width, up to PL E (ISO 13849) up to SIL 3 (IEC 61508)

Free Delivery to UK Mainland on orders over £25

Manufacturer New

1 available
1 - 2 w.days
£313.38 Exc. VAT
£376.06 Inc. VAT

Manufacturer New

Available for Back Order
£339.42 Exc. VAT
£407.30 Inc. VAT

Manufacturer New

10 available
5 - 8 w.days
£304.22 Exc. VAT
£365.06 Inc. VAT

Direct from Manufacturer

Fetching stock
2 - 3 W.Weeks

£271.59 Exc. VAT
£325.91 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7136-6DC00-0CA0
Product Description SIMATIC DP, electronic module ET 200SP, F-DQ 8x24VDC/0.5A PP HF, 15 mm width, up to PL E (ISO 13849) up to SIL 3 (IEC 61508)
Product family Digital F-output modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,054 Kg
Packaging Dimension 6,80 x 7,50 x 3,20
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623407164
UPC 804766479489
Commodity Code 85389091
LKZ_FDB/ CatalogID ST76
Product Group 4527
Group Code R152
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 09.06.2017
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

I&M Data Yes; I&M0 To I&M3
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version V14 Sp1 With Hsp 202
Step 7 Configurable/Integrated From Version V5.5 Sp4 Hf5
Profinet From Gsd Version/Gsd Revision V2.31

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Power Supply According To Nec Class 2 Required No
Input Current
Current Consumption (Rated Value) 75 Ma; Without Load
Current Consumption, Max. 21 Ma; From The Backplane Bus
Output Voltage / Header
Rated Value (Dc) 24 V
Power
Power Available From The Backplane Bus 70 Mw
Power Loss
Power Loss , Typ. 3 W
Address Area
Address Space Per Module
Inputs 6 Byte; 5 Bytes Non-Rioforfa; 6 Bytes Rioforfa
Outputs 6 Byte; 5 Bytes Non-Rioforfa; 6 Bytes Rioforfa
Hardware Configuration
Automatic Encoding Yes
Electronic Coding Element Type F Yes
Digital Outputs
Type Of Digital Output Transistor
Number Of Digital Outputs 8
Digital Outputs, Parameterizable Yes
Short-Circuit Protection Yes
Response Threshold, Typ. Min. 0.7 A
Open-Circuit Detection No
Limitation Of Inductive Shutdown Voltage To Typ. -39 V
Control Ling A Digital Input Yes; Digital Output, According To Iec 61131-2, Type 0.5
Switching Capacity Of The Outputs
With Resistive Load, Max. 0.5 A
On Lamp Load, Max. 2 W
Load Resistance Range
Lower Limit 48 Ω
Upper Limit 12 000 Ω
Output Voltage
For Signal "1", Min. 24 V; L+ (-0.5 V)
Output Current
For Signal "1" Rated Value 0.5 A
For Signal "0" Residual Current, Max. 0.5 Ma
Switching Frequency
With Resistive Load, Max. 30 Hz; Symmetrical
With Inductive Load, Max. 0.1 Hz; According To Iec 60947-5-1, Dc-13, Symmetrical
With Capacitive Load, Max. 2 Hz; Symmetrical
On Lamp Load, Max. 10 Hz; Symmetrical
Total Current Of The Outputs
Current Per Channel, Max. 0.5 A; Note Derating Data In The Manual
Current Per Module, Max. 3 A; Note Derating Data In The Manual
Total Current Of The Outputs (Per Module)
Horizontal Installation
— Up To 40 °C, Max. 3 A
— Up To 50 °C, Max. 2.5 A
— Up To 60 °C, Max. 2 A
Vertical Installation
— Up To 50 °C, Max. 2 A
Cable Length
Shielded, Max. 100 M
Unshielded, Max. 100 M
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Substitute Values Connectable No
Alarms
Diagnostic Alarm Yes
Diagnostics Indication Led
Run Led Yes; Green Led
Error Led Yes; Red Led
Monitoring Of The Supply Voltage (Pwr-Led) Yes; Green Pwr Led
Channel Status Display Yes; Green Led
For Channel Diagnostics Yes; Red Led
For Module Diagnostics Yes; Green/Red Diag Led
Potential Separation
Potential Separation Channels
Between The Channels No
Between The Channels And Backplane Bus Yes
Between The Channels And The Power Supply Of The
Electronicsno
Isolation
Isolation Tested With 707 V Dc (Type Test)
Standards, Approvals, Certificates
Suitable For Safety Functions Yes
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 88.3 Kg
— Global Warming Potential, (During Production) [Co2
Eq]13.1 Kg
— Global Warming Potential, (During Operation) [Co2 76.6 Kg
Eq]
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-1.37 Kg
Highest Safety Class Achievable In Safety Mode
Performance Level According To Iso 13849-1 Ple
Category According To Iso 13849-1 Cat. 4
Sil Acc. To Iec 61508 Sil 3
Probability Of Failure (For Service Life Of 20 Years And Repair Time Of 100 Hours)
— Low Demand Mode: Pfdavg In Accordance With
Sil3< 6.00E-05
— High Demand/Continuous Mode: Pfh In Accordance
With Sil3< 2.00E-09 1/H

Ambient Temperature During Operation

Horizontal Installation, Min. 0 °C
Horizontal Installation, Max. 60 °C
Vertical Installation, Min. 0 °C
Vertical Installation, Max. 50 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 4 000 M; With Derating

Dimensions

Width 15 Mm
Height 73 Mm
Depth 58 Mm
Weight S
Weight , Approx. 48 G