Omron

ZC-Q2255

ZC-Q2255 Omron

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for ZC-Q2255 Omron

ZC-Q2255 Omron - Standard sensitivity, IP67, Snap action, Self-reset mechanism, Single-Pole, Double-Throw type, SPDT, Panel mount roller plunger

Extended Description for ZC-Q2255 Omron

ZC-Q2255 Omron - Omron Plunger Limit Switch, NO/NC, IP67, SPDT, 250V ac Max, 10A Max

Free Delivery to UK Mainland on orders over £25

Ratings / Performance

Actuator Panel mount roller plunger
Contact resistance (Measuring method is contact resistance meter.)
Dielectric strength (50/60 Hz for 1 min)
Ratings (AC): Non-Inductive load Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Protective circuit Short-circuit protective device: 10 A fuse type gG (IEC269)
Ratings (DC): Non-Inductive load Rated voltage: 250 VDC / Resistive load: 0.25 A(NC) 0.25 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Operating mechanism Snap action
Vibration resistance (Malfunction) Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
Ratings (DC): Inductive load Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)
Ratings (AC): Inductive load Rated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Pollution degree 3 (EN60947-5-1)
Insulation resistance (at 500 VDC Megger)
Mounting specification Side mounting
Permissible operating frequency (Mechanically) 120 operations / 1 minute Max.
Dielectric strength Between each terminal of the same polarities: 1000 V
Ratings (DC): Non-Inductive load Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Protective circuit Classification of protection against electric shock: Class II
Degree of protection IEC60529 (JEM): IP67
Insulation resistance Between live-metallic part and ground: 100 MΩ
Service life General type
Contact configuration Single-Pole, Double-Throw type
Mounting specification Panel mounting
Contact resistance 15 mOhm Max. (Initial value)
Dielectric strength Between each terminal and non-live-metallic part: 2000 V
Durability (Electrically) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Insulation resistance Between each terminal of the same polarities: 100 MΩ
Dielectric strength Between live-metallic part and ground: 2000 V
Shape/Structure Enclosed Limit switches
Ambient humidity Operating: 35 to 95%
Operating Position (OP) Standard value 47.4 +/- 0.8 mm
Protective circuit Switch category: D (IEC335)
Movement Differential (MD) Standard value 0.2 mm Max.
Ratings (DC): Inductive load Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Durability (Mechanically) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Ratings (AC): Inductive load Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
Ratings (DC): Inductive load Rated voltage: 8 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Insulation resistance Between each terminal and non-live-metallic part: 100 MΩ
Pre-Travel (PT) Standard value 1.5 mm Max.
Permissible operating frequency (Electrically) 20 operations / 1 minute Max.
Durability (Mechanically) 10,000,000 operations Min. (No load) * When operate the actuator with the specified value of the Over Travel. (No load)
Shock resistance (Destruction) 1,000 m/s2
Switching mechanism Self-reset mechanism
Release Force (RF) Standard value Min. 4.9 N
Over-Travel (OT) Standard value 3 mm Min.
Ratings (DC): Non-Inductive load Rated voltage: 125 VDC / Resistive load: 0.5 A(NC) 0.5 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
Contact form SPDT
Operating Force (OF) Standard value Max. 11.8 N
Ratings (DC): Inductive load Rated voltage: 30 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Inrush current NC: 30 A
Permissible operating speed 0.05 mm/s to 0.5 m/s
Frequency 50/60 Hz
Inrush current NO: 15 A
Durability (Electrically) 500,000 operations Min. (Resistive load 10 A at 125 VAC) * When operate the actuator with the specified value of the Over Travel. (Resistive load 10 A at 125 VAC)
Ratings (DC): Inductive load Rated voltage: 14 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Ratings (AC): Non-Inductive load Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2.5 A(NC) 1.25 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Ambient temperature Operating: -10 to 80 °C
Load General load
Shock resistance (Malfunction) Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2.